Laserfiche WebLink
File No. 20-1008-36 KLEINFELDER <br /> May 20, 1996 <br /> Page 4 of 9 <br /> Dry Laboratory specified <br /> Test Moisture Density Compaction Relative Relative <br /> No. Date Test Location %Dr9 Wt. P.C.F. Curve No. Compaction Compaction <br /> CLAY BARB E+R BAYER <br /> 83 11-18 N8620 E9500 10.9 121 8 93 90 <br /> 84 11-18 N8620 E9425 11.4 123 8 95 90 <br /> 85 11-18 N8625 E9350 13.3 122 8 94 90 <br /> 86 11-18 N8700 E9410 11.8 122 8 93 90 <br /> 87 11-22 N8750 E9500 11.6 118 9 94 90 <br /> 88 11-22 N8650 E9500 11.3 121 9 96 90 <br /> 89 11-22 N8625 E9580 11.0 119 9 94 90 <br /> 90 11-22 N8480 E9690 11.6 118 9 94 90 <br /> 91 11-22 N8405 E9750 12.0 125 8 96 90 <br /> 92 11-22 N8550 E9850 12.1 124 8 95 90 <br /> 93 11-22 N8490 E9775 11.9 121 8 93 90 <br /> 94 11-22 N8625 E9825 13.2 119 9 94 90 <br /> 95 11-22 N8550 E9700 11.6 124 8 95 90 <br /> 96 11-22 N8600 E9675 12.3 122 8 94 90 <br /> 97 11-22 N8680 E9750 11.4 121 8 93 90 <br /> 98 11-22 N8710 E9650 11.3 121 8 93 90 <br /> 99 11-22 N8750 E9600 12.4 126 8 96 90 <br /> 100 11-22 N8800 E9600 12.2 123 8 94 90 <br /> R11-28 N8250 E9125 10.7 122 10 96 90 <br /> 1 2 11-28 N8200 E9175 11.7 117 10 92 90 <br /> 103 11-28 N8850 E9625 9.6 124 8 95 90 <br /> 104 11-28 N8775 E9700 11.6 124 8 95 90 <br /> 105 11-28 N8725 E9810 11.6 124 8 95 90 <br /> 106 11-28 N8675 E9810 11.2 122 8 94 90 <br /> 107 11-28 N8525 E9900 11.1 123 8 94 90 <br /> 108 11-28 N8590 E9950 11.2 117 8 90 90 <br /> 109 11-28 N8650 E9900 11.6 124 8 95 90 <br /> 110 11-28 N8750 E9875 10.6 124 8 95 90 <br /> 111 11-28 N8800 E9775 10.8 122 8 93 90 <br /> 112 11-28 N8875 E9675 11.2 122 8 94 90 <br /> 113 11-28 N8825 E9700 11.2 122 11 96 90 <br /> 114 11-28 N8800 E9875 10.7 123 11 96 90 <br /> 115 11-28 N8725 E9925 12.1 124 11 97 90 <br /> 116 11-28 N8690 E9925 10.6 117 11 92 90 <br /> 117 11-28 N8650 E10050 9.2 116 11 90 90 <br /> 118 11-29 N8950 E9750 12.6 119 8 92 90 <br /> 119 11-29 N8925 E9825 12.2 123 8 94 90 <br /> 120 11-29 N8875 E9900 12.9 121 8 93 90 <br /> 121 11-29 N8825 E9925 13.0 125 8 96 90 <br /> 11-29 N8775 E9990 11.9 121 8 93 90 <br /> 11-29 N8700 E10000 13.1 114 9 91 90 <br /> 124 11-29 N8775 E10050 12.4 116 9 92 90 <br /> Accepted engineering and testing procedures were used for these testa. We do not undertake the guarantee of construction,nor do we relieve the contractor of his primary responsibility to produce <br /> a completed project confonning to the project plans and specifications. Copyright 1996 Kieinfelder,Inc. <br />