My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
CORRESPONDENCE_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2021 2:41:31 PM
Creation date
7/3/2020 11:04:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2011
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
} <br /> r Monitoring Report Compliance Checklist 3 <br /> Discharges Regulated by Title 27 and/or Part 258 <br /> Reference Parameter Yes No N/A RWQCB <br /> Reviewer Comment <br /> WDRs/MRP/ Groundwater Monitoring X <br /> Standard <br /> Provisions 1. Are all groundwater Field <br /> (1993,1997,2000, Parameters Monitoring Parameter, <br /> 2003) and COCs(if required)sampled <br /> and analyzed? <br /> in. Have any groundwater X Wells MW-5 and MW-8 reported continued <br /> concentration limits been detections of VOCs. PCE was detected in <br /> exceeded? If yes,identify in both wells at concentrations 4.9 µg/L and 3.8 <br /> comments. µg/L. Both concentrations are increases over <br /> the 3`d Quarter results. Public Health Goal <br /> for PCE is 0.06 gg/L. The PCE/TCE/cis-1,2 <br /> DCE chlorinated series is evident in wells <br /> MW-5 and MW-8. <br /> n. Is there a description and X Shallow GW flows SW toward well MW-8. <br /> graphical presentation of Deep aquifer flows NE into valley <br /> groundwater flow direction and <br /> gradient? <br /> o. Monitoring Wells: Is there a X <br /> description,method,and time of <br /> water level measurement and well <br /> recovery time? <br /> p. Purging: Is there a description of X <br /> the purging method,purge pump <br /> and its placement, and field <br /> parameters? <br /> WDRs Semiannual/Annual Monitoring X <br /> Standard Report(when applicable) <br /> Provisions <br /> (1993,1997,2000, q. Are all monitoring parameters and <br /> 2003) COCs graphed so as to show <br /> historical trends at each <br /> Monitoring Point and Background <br /> Monitoring Point? <br /> r. Is all monitoring analytical data X <br /> obtained in the last year presented <br /> in tabular form,as well as on a <br /> diskette or CD? <br /> s. Is there a comprehensive X Staff agrees that LFG extraction has had <br /> discussion of the compliance positive effect in controlling methane at <br /> record and the result of any perimeter of landfill. However,continued <br /> corrective actions? GW impacts have not been abated since . <br /> system was installed. Refuse found outside <br /> of WMU is likely the source of continued <br /> impacts. Closure cap must be extended. <br />
The URL can be used to link to this page
Your browser does not support the video tag.