EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
Archived Reports
>
ARCHIVED REPORTS_2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:38 PM
Creation date
7/3/2020 11:05:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2012
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_2012.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />C. Shop Drawings: <br />1. One complete set of reviewed shop drawings, including manufacturer's printed <br />catalog cuts and data, shall be collected and maintained by the Contractor for <br />record purposes. <br />2. Shop drawings shall be filed and maintained by the Contractor, separate from <br />project drawings. Shop drawings shall be filed in 3 -ring binders with drawings <br />folded to fit heavy duty top loading clear view sheet protectors to the greatest <br />' extent possible and shall be indexed in accordance with the Specification <br />Division Format. <br />3. Shop drawings shall be delivered by the Contractor in new paperboard boxes <br />manufactured specifically for the storage of file folders. Boxes shall have <br />covers and cutout handles and shall be accurately identified as to the contents. <br />D. Record Survey Drawings <br />1. The Contractor shall prepare and submit for review and approval, the Record <br />' Survey Drawings, and certification letter as described in Section 01052, <br />Layout of Work and Surveys to the Engineer. <br />SHAW ENVIRONMENTAL, INC. <br />San Joaquin County — Extension of Cap Corral Hollow Sanitary Landfill — CH Closure Cap Ext Proj_Technical Specs -4-19-12 Revl.DocRev. 0, 04/05/2012 <br />tProject Record Documents <br />01720-3 <br />shown in detail. All main runs, whether piping, conduit, ductwork, or drain <br />lines shall be located, in addition, by dimension and elevation. <br />6. <br />No work shall be permanently concealed until the required information has <br />been recorded. <br />7. <br />. Where the Engineer's drawings are not of sufficient size, scale, or detail, the <br />Contractor shall furnish his own drawings for incorporation of details and <br />dimensions. <br />8. <br />The Contractor shall submit the Record Drawings to the Engineer before the <br />County's acceptance of the Work. <br />B. Addenda and Change Orders: <br />1. <br />Changes to the Construction Drawings shall be by the Engineer, and will be <br />identified by Addendum, Change Order or Engineer's Field Order number, and <br />effective date. <br />2. <br />When changes to the Construction Drawings are issued by the Engineer as the <br />basis of or along with addenda, these revised drawings shall be incorporated by <br />the Contractor into the Record Drawings with appropriate annotation. <br />C. Shop Drawings: <br />1. One complete set of reviewed shop drawings, including manufacturer's printed <br />catalog cuts and data, shall be collected and maintained by the Contractor for <br />record purposes. <br />2. Shop drawings shall be filed and maintained by the Contractor, separate from <br />project drawings. Shop drawings shall be filed in 3 -ring binders with drawings <br />folded to fit heavy duty top loading clear view sheet protectors to the greatest <br />' extent possible and shall be indexed in accordance with the Specification <br />Division Format. <br />3. Shop drawings shall be delivered by the Contractor in new paperboard boxes <br />manufactured specifically for the storage of file folders. Boxes shall have <br />covers and cutout handles and shall be accurately identified as to the contents. <br />D. Record Survey Drawings <br />1. The Contractor shall prepare and submit for review and approval, the Record <br />' Survey Drawings, and certification letter as described in Section 01052, <br />Layout of Work and Surveys to the Engineer. <br />SHAW ENVIRONMENTAL, INC. <br />San Joaquin County — Extension of Cap Corral Hollow Sanitary Landfill — CH Closure Cap Ext Proj_Technical Specs -4-19-12 Revl.DocRev. 0, 04/05/2012 <br />tProject Record Documents <br />01720-3 <br />