the landfill. This would appear to indicate that the landfill has no affect on the deep aquifer.No <br /> primary MCLs were exceeded this quarter in MW-7. Secondary MCLS for EC, Sulfate and TDS <br /> were exceeded in MW-7 this quarter. However,the EC, Sulfate, and TDS levels are consistent <br /> with the general historical conditions at this well. <br /> Based on output from the Sanitas statistical software, an increasing trend is reported in <br /> Bicarbonate Alkalinity, whereas a decreasing trend is reported in the concentration of Chloride, <br /> and Sulfate (Table 3). <br /> No VOCs were reported at this well this quarter. VOCs were last detected in this well on <br /> April 23, 2004;these detections are believed to have been introduced during well construction, <br /> and do not indicate groundwater impact from the landfill. <br /> Surface water <br /> Surface water samples were last collected on January 27, 2011. All concentrations of field <br /> parameters and constituents of concern were below established concentration limits where the <br /> limits could be determined. <br /> Unsaturated Zone Soil Pore Gas <br /> The Monitoring and Reporting program for the landfill requires semi-annual VOC testing by <br /> TO-14 analysis. Soil Gas samples were not collected this quarter,but will be collected and <br /> analyzed during the 2nd Quarter 2012. Soil gas samples were last collected on July 28, 2011. <br /> This information was included in the third quarter report. <br /> Before sampling,the concentration of major gasses (Methane, Carbon Dioxide, and Oxygen) and <br /> pressure were measured using a CES-LANDTEC GEMTm2000 portable gas detector. The <br /> GEMTm2000 is operated until a steady-state gas composition indicated that the well was purged <br /> and ready for sampling. Soil gas samples are collected in 1-liter Summa canisters and sent for <br /> VOC analysis by EPA method TO-14. <br /> The probes for TO-14 sampling were selected in 2006, with samples collected from the probe <br /> most likely to have the highest VOC concentration: the sample was.taken from the probe with <br /> the highest methane content. If methane was not detected, then the sample was collected from <br /> the deepest probe. The probes selected in 2006 continue to be sampled. <br /> VOCs were detected in all seven soil gas well probes during this third quarter monitoring event. <br /> The highest VOC concentration was found in well SG-6D. No "upwind" air sample was taken. <br /> Groundwater Direction and Flow Rate <br /> Shallow Aquifer <br /> Groundwater elevations at wells SB-1, MW-4, MW-5, and MW-8 indicate that the groundwater <br /> flow gradient in the shallow perched aquifer continues to be to the southwest and into the landfill <br /> from SB-1 location(Figure 2 and Appendix G). The average groundwater velocity is calculated <br /> to be 2.27 ft/yr based on a gradient of 0.0081 feet per foot. The current water levels are similar <br /> Corral Hollow Sanitary Landfill 12 Department of Public Works/Solid Waste <br /> 1s`Quarter 2012 Groundwater Monitoring County of San Joaquin—April 16,2012 <br />