Laserfiche WebLink
Monitoring Report Compliance Checklist 3 <br /> Discharges Regulated by Title 27 and/or Part 258 <br /> Reference Parameter Yes No N/A RWQCB <br /> Reviewer Comment <br /> WDRs/MRP/ Groundwater Monitoring X <br /> Standard <br /> Provisions 1. Are all groundwater Field <br /> (1993,1997,2000, Parameters Monitoring Parameter, <br /> 2003) and COCs(if required)sampled <br /> and analyzed? <br /> in. Have any groundwater X VOCs detected in well MW-2 <br /> concentration limits been (Tetrachloroethene and <br /> exceeded? If yes,identify in dichlorodifluoromethane). A statistically <br /> comments. significant trend observed for Chloride. <br /> Turbidity also increasing in well MW-2. See <br /> comments below. <br /> n. Is there a description and X Groundwater flow has shifted direction to the <br /> graphical presentation of southeast. <br /> groundwater flow direction and <br /> gradient? <br /> o. Monitoring Wells: is there a X <br /> description, method,and time of <br /> water level measurement and well <br /> recovery time? <br /> p. Purging: Is there a description of X <br /> the purging method,purge pump <br /> and its placement,and field <br /> parameters? <br /> WDRs Semiannual/Annual Monitoring <br /> Standard Report(when applicable) <br /> Provisions <br /> (1993,1997,2000, q. Are all monitoring parameters and <br /> 2003) COCs graphed so as to show <br /> historical trends at each <br /> Monitoring Point and Background <br /> Monitoring Point? <br /> r. is all monitoring analytical data <br /> obtained in the last year presented <br /> in tabular form,as well as on a <br /> diskette or CD? <br /> s. is there a comprehensive <br /> discussion of the compliance <br /> record and the result of any <br /> corrective actions? <br />