• Davis Instruments Weather Wizard III Anemometer with continuous data recorder <br /> for meteorological conditions in accordance with SJVAPCD Rule 4642 Section <br /> 6.1.1.3. <br /> MONITORING PROCEDURE <br /> The surface emission monitoring procedure is as follows: <br /> The OVA inlet will be moved around over the surface of the landfill within three inches in <br /> a grid like parallel paths not more than 90 feet apart (Figure P-1). Cracks, holes and <br /> other breaks in the closure cap surface will also be tested. Surface emissions readings <br /> will be recorded every 30 seconds or when significantly different values are measured. <br /> During surface emissions testing, weather conditions will be recorded in accordance with <br /> Rule 4642 requirements on the test date. <br /> TESTING RESULTS <br /> SJVAPCD will be notified of each test thirty (30 s in advance. Test results will be <br /> ) days <br /> submitted to SJVAPCD and local enforcement authorities within 60 days of completion of <br /> testing. <br /> MITIGATION MEASURES <br /> Mitigation procedures will be implemented if emissions are detected above 1000 ppmv. <br /> Mitigation implementation procedures may include placing clay, grout, or bentonite slurry <br /> in apparent holes or cracks in the clay barrier, placing an additional clay barrier or soil <br /> over the specified area, or increasing vacuum at landfill gas extraction wells in the vicinity <br /> of the emissions to influence more landfill gas away from the surface. <br /> Harney Lane Sanitary Landfill San Joaquin County <br /> Surface Emissions Protocol P-2 Department Of Public Works <br /> Solid Waste Division <br />