Laserfiche WebLink
3D ENERGY CONSUMPTION <br /> The annual energy requirements for the transfer station operation <br /> are listed in Table 3-5. Assumptions used in arriving at the equiv- <br /> alent Btu values are as follows : <br /> 11, 000 Btu/Kwh <br /> 139, 000 Btu/gal. of vehicle fuel <br /> TABLE 3-5 <br /> POWER CONSUMPTION - TRANSFER STATION <br /> Hydraulic Compaction Direct Dump <br /> Equivalentl Equivalent <br /> Unit Btu (MMBTU) Unit Btu (MMBTU) <br /> General Station Power 34,800 Kwh 382.8 34,800 382.8 <br /> Kwh <br /> Stationary Compactor 200,750 Kwh 2,208.3 -- -- <br /> Rolling Stock 10,038 gal. 1,395.2 18,402 2,557.9 <br /> Total 3,986.3 2,940.7 <br /> MMBTU MMBTU <br /> 1 MMBTU = One Million BTU <br /> These tabulations do not reflect the energy consumed in the haul <br /> or dumping operation. They are outlined in Chapter 4. <br /> _ 15 _ <br />