3-14 <br /> ♦ Incorporating careful control of processing temperatures to maintain the rate of <br /> decomposition. Additionally, as required in 14 CCR, Sections 17863.4 and <br /> 18227(n), an Odor Impact Minimization Plan (OIMP) is included as Appendix E-1. <br /> Odors are not anticipated from residue storage since residue will be stored for no more than <br /> 24 hours. If persistent odors are produced, additional odor control techniques that may be <br /> implemented include: <br /> ♦ Maintaining a carbon-to-nitrogen (C:N) ratio above 25:1 in initial mixes of high <br /> nitrogen materials; <br /> ♦ Placing a layer of cured compost over raw compost materials to act as an odor trap <br /> and serve as insulation; and, <br /> ♦ Using an organic odor neutralizer. <br /> The EHD will be contacted should the site receive any odor complaints. <br /> 3.6.3 Noise Control <br /> Noise at the site includes traffic noise generated by trucks and other vehicles travelling <br /> along Austin Road to the landfill and RRF/Compost Facility and noise generated by the <br /> equipment used in RRF/Compost Facility operations. Noise levels of onsite equipment are <br /> controlled by proper maintenance of mufflers to factory specifications. The EHD will be <br /> contacted should the site receive any noise complaints. Additionally, there shall be no <br /> ancillary or facility operations (i.e., heavy equipment operations within 1,500 feet of any <br /> occupied residence) outside of the permitted hours of operation. <br /> Noise levels are not likely to create health hazards to persons using the site due to the use <br /> of mufflers on heavy equipment. Protective ear wear is provided to all employees. Due to <br /> the remote location of the site, noise levels are not likely to create health hazards to nearby <br /> residents. The EHD will be contacted should the site receive any complaints. <br /> In general, the major sources of noise at the Compost Facility/RRF will be the grinder and <br /> the Windrow turner, if used. These machines typically produce sound levels in the range of <br /> approximately 85 to 90 decibels. Since the estimated sound level at 200 feet is <br /> approximately that of the human voice during normal conversation, noise should not be a <br /> health hazard to persons working approximately 200 feet from the equipment. A noise level <br /> study conducted for a tub grinder manufacturer shows the following sound pressure levels: <br /> within 50 feet, 85.2 decibels; within 100 feet, 78.4 decibels; and within 200 feet, 73.5 <br /> decibels. <br /> It should be noted that noise produced at the facility also complies with provisions of the <br /> San Joaquin County Development Code, Title 9, Section 9-1025.9 as specified in SWFP No. <br /> 39-AA-0020. <br /> Due to the site's remote location, the noise produced will not create an offsite concern; <br /> therefore, no special noise control devices will be needed at the RRF/Compost Facility. <br /> 3.6.4 Dust Control <br /> Dust is controlled at the site by (1) proper maintenance of haul roads (paving, grading, and <br /> watering), (2) application of fine water spray (dictated by the weather conditions and/or on <br /> an as-needed basis) on the active soil-covered work areas, soil excavation areas, and soil <br /> 0 stockpile areas where conditions may result in fugitive dust; (3) application of organic dust <br /> Forward Composting Facility SWT Engineering <br /> Report of Composting Site Information-November 2014 <br /> z:\prcjects\allied waste\forward\resource recovery facility\5 yr permit rvw 2013-14\resi 2014\text\sec 3.doc <br />