Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for QUICKI KLEEN CAR WASH as of May06 , 2020 . <br /> Open violations from October 30, 2019 inspection <br /> Violation #206 - Failure to comply with UST operating permit conditions . <br /> Close of escrow was on 8/26/2019 . CERS submittal was made on 10/7/2019 , more than 30 days after escrow <br /> closed . Permit may be transferred to a new underground storage tank owner if the complete submittal is made to <br /> the California Environmental Reporting System or a local reporting portal within 30 days of the change in ownership . <br /> Immediately complete and submit all required CERS documents for review by the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #209 - Failure to conduct the designated UST operator visual inspection at least once every 30 <br /> days . <br /> The following was observed on the designated operator' s monthly inspection reports : <br /> -Section V of the reports were missing follow up actions about scheduling an Overfill Prevention Equipment <br /> Inspection . <br /> -Section VI of the report was missing date , name and signature of the owner/operator. <br /> -Secondary Containment test date was incorrectly stated . <br /> During the visual inspection , the designated operator shall check all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report . Ensure that designed operators <br /> performing visual inspections at this facility are including all of the required information on the reports . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #211 - No employee present that were trained in the operation and maintenance of the UST system <br /> byaDO . <br /> Harry Singh has been working at this facility for more than a month . The designated operator employee training for <br /> Harry Singh was not performed . The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months . The training shall be conducted before the <br /> individual performs the duties of a facility employees . The training shall include , but is not limited to : <br /> 1 . Operation of the UST system in a manner consistent with the facility' s best management practices <br /> 2 . Employee ' s role with regard to monitoring equipment as specified in the facility' s monitoring plan <br /> 3 . Employee ' s role with regard to spills and overfills as specified in the facility' s response plan <br /> 4 . Name of the contact person (s) for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies , leak detection , monitoring alarms , spills and overfills . At least <br /> one of the facility employees present during operating hours shall have current training . Ensure that employees <br /> have been trained by the designated operator, maintain the list on site , and submit a copy of the training records to <br /> the EHD . <br /> Page 2 of 3 <br />