Laserfiche WebLink
Page 1 of 3 <br /> LEAK DETECTIONS :.r.� G; 'i/ <br /> T E C H N O L O G I E S INC <br /> feiAY d 2 2020 <br /> Exclusive Providers for MDleak° MSleako DPleak°and <br /> PHDleak° Testing Technologies ENVIRONMENTAL HEALTH <br /> 1889 N Oracle Road ❑ Tucson, AZ 85705 ❑ Phone 855-255-5325 ❑ FAX: 1-520.509-3720 <br /> Facility Certification CONFIDENTIAL <br /> Test Type: California ELD New Construction Test MD/MCleak <br /> Facility Name: Lodi 76 Job#: 4204 <br /> Prepared For: MVP Petroleum Engineering,Inc PO#: NA <br /> Site Address: 141 E Harney Lane <br /> City: Lodi Primary Test Leak Rate: 0.005¢ph <br /> State and Zip: CA 95240 Secondary Test Leak Rate: 0.1 euh <br /> Start Date: 5/21/2020 End Date: 5/22/2020 <br /> SYSTEM TK-1-87 TK-2-91 TK-3-DSL <br /> Product Primary MDleak: PASS PASS PASS <br /> Product Secondary: PASS PASS PASS <br /> Vent Primary MDleak: PASS PASS PASS <br /> Vent Secondary: PASS PASS PASS <br /> VR Primary MDleak: PASS PASS NA <br /> VR Secondary: PASS PASS NA <br /> MCleak ELD Tank: PASS PASS PASS <br /> 72 Hr.Out of Service: Confirmed Confirmed Confirmed <br /> MDleak ELD Tank: NA NA NA <br /> Turbine Sump MDleak: PASS PASS PASS <br /> Turbine Head MDleak: PASS PASS PASS <br /> F/Va or Sump MDleak: PASS PASS PASS <br /> UDC's MDleak: <br /> Fill Bucket MDleak: PASS PASS PASS <br /> —Vapor Bucket MDleak: PASS PASS I NA <br /> Vent Box MDleak: PASS PASS PASS <br /> Fill Spill Bucket H do: PASS PASS PASS <br /> Vapor Bucket Hydro: PASS PASS NA <br /> STP Sump Elect DPleak: PASS PASS PASS <br /> Certifying Field Technician: Ricardo Gonzalez State Lic.#: 04-1695 <br /> Certification Leak Rate: 0.005 gph <br /> - ♦_2__4 - <br /> r✓`y/DV <br /> Certifying Technician Signature: e Date: 5/22/2020 <br /> This is a statement to confirm that the components listed above, at the time of testing, have been tested to a leak <br /> sensitivity listed above by using one or more of the following DPleak®, MDleak® and PHDleak® EPA aproved Methods. <br /> The DPleak®, MDleak® and PHDleak® Methods are the most versatile and comprehensive testing procedures offered to <br /> the petroleum industry. All petroleum owners and contractors which utilize the DPleak®, MDleak® and PHDleak® Method <br /> can be assured that their facility has passed the Nation's highest standard in preventative leak detection. <br /> I declare under penalty of perjury that I am a licensed tester in one of the above methods listed by the National <br /> Workgroup on Leak Detection Evaluations (NWGLDE) organization and that the information contained in this report is <br /> true and correct to the best of my knowledge. <br /> If you have any questions on the testing please do not hesitate to call.@ 855-255-5325. <br /> Office use only <br /> Statement Confirmed by: Date: 5/22/2020 <br />