Page 2 <br />' Mr. Timothy J. Cuellar <br /> Advanced GeoEnvironmental Inc. <br />' e o filtration media based upon the information <br /> The estimated usage f P <br /> Iyou provided us, is as followS: <br /> Activated carbon: 39 pounds per day <br /> ISunSolve Media: 9.5 pounds per day <br /> In respect to the groundwater recovery pump ( down well ) and <br /> electrical control panel, we are also Including these In our proposal. <br /> Following is a list of materials included in the above-described system. <br /> I <br /> Wde,r Treatment Syst�rn: <br /> 500 gallon holding tank, ODPE, with fluid level sensors for control of <br /> groundwater and process control pumps, visual fluid level sight glass, <br /> drain valve, removable ltd. <br /> Process pump, electric, 1.Q HP TECIF 230 volts single phase, <br />' centrifugal, with flow control valve and pressure gauge. <br /> Electric control panel, for process pump, w/inputs for fluid level pump <br /> sensors, 230 volt, single phase. <br /> Suspended solids separator, bag type, steer, rated at 30 gpm <br /> maximum, replaceable bags. <br /> I 4 each, SUN-AG Model SA1OOO-L 30 Activated Carbon Adsorbers, <br /> maximum working pressure 40 psi, 2" inlet/outlets ( two for GAC, two <br /> flor SunSolve). <br /> 2,000 pounds liquid phase granular activated carbon, virgin coconut � <br /> shell, and 3,000 pounds SunSolve media for the initial fill of the <br /> adsorber systems. <br /> Flow meter and total flow indicator, battery powered. <br /> I <br />