My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1229
>
2300 - Underground Storage Tank Program
>
PR0527041
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2020 9:34:18 AM
Creation date
7/14/2020 1:42:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0527041
PE
2351
FACILITY_ID
FA0018327
FACILITY_NAME
MANTECA GAS & FOOD*
STREET_NUMBER
1229
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20809015
CURRENT_STATUS
01
SITE_LOCATION
1229 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AN ]OA UI I <br />C)U NTY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />MANTECA GAS & FOOD* <br />Facility Address: <br />1 1229 E LOUISE AVE, MANTECA <br />Date: <br />August 19, 2019 <br />UST System Observations <br />313 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failure to construct, operate, and maintain primary containment as product -tight <br />V ❑ R ❑ COS <br />314 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failed to have secondary containment or secondary containment not tight <br />V ❑ R ❑ COS <br />315 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />❑ V ❑ R ❑ COS <br />316 <br />HSC 25290.1(c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />❑ V ❑ R ❑ COS <br />317 <br />CCR 2636, 2643(c)(1), <br />2666(f) <br />Line leak detector (LLD) not installed <br />❑ V ❑ R ❑ COS <br />318 <br />CCR 2666(c), 2643(c) <br />(1) <br />Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch <br />❑ V ❑ R ❑ COS <br />319 <br />CCR 2635, 2637.1, <br />2665, 2712 <br />No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested <br />❑ V ❑ R ❑ COS <br />320 <br />CCR 2635, 2637.2, <br />2665, 2712 <br />Failure to comply with the installation, inspection, or record keeping of the overfill prevention■ <br />V n R ❑ COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R ❑ COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />n V n R n COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />n V ❑ R ❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />n V ❑ R ❑ COS <br />327 <br />CCR 2631.1, 2660(m) <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />n V ❑ R ❑ COS <br />329 <br />HSC 25298; CCR 2670, <br />2672 <br />Failed to comply with all permanent closure requirements <br />n V ❑ R ❑ COS <br />330 <br />CCR 2636(f), 2666(c), <br />2666(f) <br />No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2630(d), 2641(a) <br />Liquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot). <br />❑ V ❑ R ❑ COS <br />332 <br />CCR 2631(b&d), <br />2666(b&e) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />n V ❑ R ❑ COS <br />333 <br />CCR 2635, 2636(b), <br />2662, 2712 <br />Failure to comply with the cathodic protection system requirements <br />n V n R n COS <br />334 <br />CCR 2666(b)(2) <br />Single -walled pipe not upgraded to double -walled interstitially monitored pipe during repair <br />n V ❑ R ❑ COS <br />335 <br />CCR 2630, 2632, 2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third -party <br />❑ V ❑ R ❑ COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3), <br />2641(b) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />No monitoring or record maintenance for single -walled conventional suction systems (pre -Jan 1984). <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d), 2661(f) <br />Failure to conduct 0.1 gph test for single -walled conventional suction systems (pre -Jan 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e), 2661(f) <br />I Biennial 0.1 gph line integrity test for single -walled gravity piping not performed (pre -Jan 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />EHD 23-01 Rev. 09/28/2018 <br />Page 3 of 5 <br />FA0018327 PRO527041 SCO01 08/19/2019 <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 <br />Underground Storage Tank Program OIR <br />www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.