Laserfiche WebLink
au`" ? SAN JOAQUIN Environmental Health Department <br /> iCOUNTY Jasjit Kang , REHS , Director <br /> crP <br /> rFoGreatness grows here . Muniappa Naidu, REHS , Assistant Director <br /> a?� <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> November 24 , 2020 <br /> Victor Hassan <br /> H & S Energy Products , LLC <br /> 2860 N . Santiago Blvd . <br /> Orange , CA 92867 <br /> Re : H &S Energy Products , #3035 SR0081688 <br /> 192 Lathrop Rd . , Lathrop , CA 95330 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Convert (e) 87 siphon tank to E85 <br /> • Remove manifold piping between the two 87 tanks <br /> • Remove four middle dispensers and under dispenser containment sumps ( UDCs ) <br /> • Replace eight dispensers with conversion frames <br /> • Install piping from the E85 tank to two dispensers <br /> • Replace the overfill prevention flapper on the new E85 tank <br /> • Replace the annular sensor on the new E85 tank <br /> • Replace the turbine and fill sump sensors on the new E85 tank <br /> • Cold start the monitoring panel <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustsigov . org to arrange the following appointments ( a 48 - hour <br /> notice is required for inspection appointments ) . <br /> a . Primary piping soap test of all piping and penetrations ( product , vapor recovery , and <br /> vent) : One - hour pneumatic pressure test at 110 % of operating pressure , or 40 psi , <br /> whichever is greater, in accordance with manufacturer installation instructions <br /> b . Secondary piping soap test of all piping and penetrations ( product , vapor recovery , and <br /> vent) : One - hour pressure test at the manufacturer' s recommended specification . <br /> c . Verification of secondary piping slope at 1 /8 inch per foot or greater, to a containment <br /> sump with an audible/visual alarm . <br /> d . Secondary piping soap test of all piping and penetrations ( product , vapor recovery , and <br /> vent) : One - hour pressure test at the manufacturer' s recommended specification . <br /> e . Verification of all pipe setbacks , cross -overs , and burial depth according to the <br /> manufacturer' s installation instructions and verification of appropriate piping backfill . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464 -0138 1 www . sjgov . org/ehd <br />