Laserfiche WebLink
' Beacon Cardlock Station Number 610 SSB 92-1001-01 <br /> 3300 Waterloo Road <br /> Page 23 <br /> Stockton, California <br /> zone detector tube samples, all activity will cease until these concentrations diminish If PID <br /> measurements above 1,400 ppmv occur, a potential fire or explosion hazard may exist Under these <br /> circumstances, activities will be stopped until these levels are brought down. This may be accomplished <br /> by containerizing contaminated soils or liquids,covering contaminated soil, foam,visquene,or with clean <br />' soil to isolate the source <br /> 11.4 Community Protection <br />' To assure the community is not affected by our investigation, upwind and downwind monitoring with <br /> the PID will be performed if the general work area hydrocarbon level exceed 100 ppmv If site <br /> downwind monitoring indicates persistent levels above 300 ppmv at the perimeter of the work area, <br /> work will be shut down until PID readings drop below 30 ppmv Alternately, the exclusion zone may <br /> be expanded to provide additional community protection <br /> M12.0 RECORD KEEPING REQUIREMENT <br /> The following record keeping requirements will be maintained in the health and safety or program file <br /> indefinitely <br /> • Copy of this Health and Safety pian <br /> • Health and Safety training certification forms <br /> • Respirator training certification <br /> • Any accident/illness report forms <br /> • Documentation of employees medical ability to perform work and wear respirators <br /> SSB ENVIRONMENTAL CONSULTANTS, INC <br />