My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2200 - Hazardous Waste Program
>
PR0536804
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 6:15:40 PM
Creation date
7/15/2020 3:38:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0536804
PE
2229
FACILITY_ID
FA0021137
FACILITY_NAME
OILSTOP
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
01
SITE_LOCATION
301 W KETTLEMAN LN
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n HAZARDOUS MATERIAL TANK CERTIFICATION <br /> FOR <br /> HAZARDOUS WASTE HOLDING TANK <br /> Oil Stop <br /> 301 W/ Kettleman Lane <br /> Lodi CA 95240 <br /> 1.0 Purl2ose <br /> Martin Consulting Group, Inc. (MCG) has been retained and visited the Oil Stop (OS) <br /> facility on August 15, 2019. We inspected and took detailed measurements of the tanks <br /> required for the certification process. Furthermore, we were shown one (1) aboveground <br /> double walled steel storage tank which is used for hazardous waste storage, located in <br /> the basement of the facility building, open to the atmosphere with approximately several <br /> inches of tertiary containment. The Above Ground Storage Tank (AST) is a double walled <br /> storage tank (Tank)with (1-one) 1000 gallon capacity that holds waste oil. The hazardous <br /> waste tank is constructed with one (1) primary inner tank and with a single secondary <br /> outer tank that is UL certified. The waste oil is generated from facility's maintenance shop <br /> where automobile services are performed. The waste oil is transferred to the tank through <br /> a 3/4 inch reinforced rubber hose and 3/&1 inch metal piping via a gravity system to the <br /> basement, awaiting proper disposal following all local, state and federal requirements. <br /> MCG has been requested to provide a Professional Engineer (P.E.) certification of the <br /> tanks in compliance with CCR Title 22 §66265.192 or Chapter 15 Article 10. The <br /> certification at the front of this document provides a statement detailed in compliance with <br /> CCR Title 22 §66270.11(d). The tank in this study meets the containment requirements. <br /> 2.0 Tanks/Processes included in Tank Certification <br /> The tank in this review is an aboveground double walled steel storage tank. The tank is <br /> constructed with a primary inner tank with a single secondary outer tank. The waste oil is <br /> generated from facility's maintenance shop where automobile services are performed. <br /> The tank is UL Certified according to information located on a placard affixed to the tank. <br /> Hazardous Waste Tank Assessment Report Martin Consulting <br /> Oil Stop,301 W. Kettleman Lane Page 5 of 29 Group,Inc.—Structural Design <br />
The URL can be used to link to this page
Your browser does not support the video tag.