My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2200 - Hazardous Waste Program
>
PR0536804
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 6:15:40 PM
Creation date
7/15/2020 3:38:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0536804
PE
2229
FACILITY_ID
FA0021137
FACILITY_NAME
OILSTOP
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
01
SITE_LOCATION
301 W KETTLEMAN LN
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />FA0021137 PR0536804 SCO01 07/15/2019 <br />EHD 22-02 Rev. 09/27/2018 Page 7 of 9 Large Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Large Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />1 <br />Facility Address: <br />Date: <br />OILSTOP <br />301 W KETTLEMAN LN, LODI <br />July 15, 2019 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />403 <br />CCR 66265.173 Failed to keep hazardous waste containers closed except when adding or removing hazardous <br />waste. <br />Observed a blue 5 gallon open container with used paper oil filters in the hazardous waste storage area lacking a lid. <br />All hazardous waste containers shall be closed at all times except when adding or removing waste. Immediately close <br />these containers and ensure all hazardous waste containers are closed when not adding or removing waste. <br />This is a repeat violation, Class ll. <br />512 <br />CCR 66265.192(h) Failure to obtain an assessment or reassessment of a hazardous waste tank system. <br />The tank assessment for the 1000 gallon used oil tank was not available at the time of inspection. <br />The owner or operator of a hazardous waste tank shall obtain a written assessment reviewed and certified by an <br />independent, qualified, professional engineer, registered in California attesting that the system has sufficient <br />structural integrity, is acceptable for the transferring, storing, and treating of hazardous waste, and that the tanks and <br />containment system are suitably designed. <br />The hazardous waste tank assessment shall include all of the following information: <br />1. tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity (in gallons); <br />2. design standard(s), if available, according to which the tank and ancillary equipment were or will be <br />constructed and all of the following information: <br />A. material of construction; <br />B. material thickness and the method used to determine the thickness; <br />C. description of tank system piping (material, diameter); <br />D. description of any internal and external pumps; and <br />E. sketch or drawing of tank including dimensions. <br />3. documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br />age); <br />4. description and evaluation of any leak detection equipment; <br />5. description and evaluation of any corrosion protection equipment, devices, or material; <br />6. description and evaluation of any spill prevention or overfill equipment; <br />7. description and evaluation of secondary containment for the tank system including applicable secondary <br />containment for ancillary equipment as required in subsection 66265.193(f); <br />8. hazardous characteristics of the wastes that have been or will be handled. <br />Immediately have an assessment prepared for the 1000 gallon used oil tank. Submit a schedule showing when this <br />will be accomplished to the EHD. <br />This is a Class II violation. <br />FA0021137 PR0536804 SCO01 07/15/2019 <br />EHD 22-02 Rev. 09/27/2018 Page 7 of 9 Large Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.