Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> U ;� i I <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY FUEL CENTER#1769 2802 COUNTRY CLUB BLVD, STOCKTON January 08, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 306 CCR 2630(d), 2641(a) Monitoring equipment is not installed or maintained to detect a leak at the earliest <br /> opportunity. <br /> OBSERVATION: The site has flexible product piping. The piping within the UDCs has jumper cables attached. The <br /> cables curve up and around, connect to other pipes, and some Schrader valves point up instead of down. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to ensure that any <br /> releases in the product piping flows into the UDC. <br /> This is a Class II violation. <br /> 318 CCR 2666(c), 2643(c)(1) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch. <br /> OBSERVATION: The 87#1 and 91 line leak detectors failed to detect a leak when tested. <br /> REGULATION GUIDANCE:All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed leak detector(LG 113-x listed, if applicable)and obtain a permit within one business day from the EHD, if <br /> needed. If the failed leak detector can't be replaced immediately,there is a possibility that the 87 and 91 UST <br /> systems may be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 7, 2020. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> Documents provided during inspection: Return to Compliance forms <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: ! Date: January 08, 2020 Inspector: Inspector Phone: <br /> Printed Name and Title: STACY RIVERA, Lead Senior REHS (209)468-3440 <br /> l�`T rl Sandra Harbaugh, Manager <br /> FA0012764 PR0516736 SCO01 01/08/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 5 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />