Laserfiche WebLink
Facility Name: Costco # 1 091 Lodi ( Page 4) <br /> ` . Results of Vacuum/Pressure Monitoring Equipment Testing <br /> Manufacturer: Veeder-Roofi Model : 332117-OOi System Type: ❑ Pressure ® Vacuum <br /> Sensor s <br /> ID <br /> S9 Component(s) Monitored by this Sensor: 87a Product Line <br /> Sensor Functionalily Test Results : ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass : ❑ Fail <br /> s10 Component(s) Monitored by this Sensor. 87a Vapor Line <br /> Sensor Functionality Test Results : ® Pass; ❑ Fail Interstitial Communication Test Result: [0 Pass : ❑ Fail <br /> s11 Component(s) Monitored by this Sensor: 87a Vent Line <br /> Sensor Functionality Test Results . ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass : ❑ Fail <br /> s12 Component(s) Monitored by this Sensor: 87b Product Line <br /> Sensor Functionals Test Results : Z Pass; ❑ Fail Interstitial Communication Test Result: ® Pass : ❑ Fail <br /> S13 Component(s) Monitored by this Sensor: 87b Syphon Line <br /> Sensor Functionals Test Results : ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass : ❑ Fall <br /> s14 Component(s) Monitored by this Sensor: 87b Vent Line <br /> Sensor Functionalit Test Results : ® Pass; ❑ Fail: Interstitial Communication Test Result : ® Pass : ❑ Fail <br /> 0 s17 Component(s) Monitored by this Sensor: 91 Product Line <br /> Sensor Functionality Test Results : ® Pass; ❑ Fail Interstitial Communication Test Result : ® Pass : ❑ Fall <br /> S18 Component(s) Monitored by this Sensor: 91 Vent Line <br /> Sensor Functionals Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result : ® Pass : ❑ Fall <br /> S23 Component(s) Monitored by this Sensor: Additive Product Line <br /> Sensor Functionality Test Results : ® . Pass; ❑ Fail Interstitial Communication Test Result : <br /> ® Pass : ❑ Fail <br /> s24 Component(s) Monitored by this Sensor:Additive Vent Line <br /> Sensor Functionality Test Results: ® Passe ❑ Fail Interstitial Communication Test Result : ® Pass : ❑ Fail <br /> How was interstitial communication verified ? <br /> ® Leak Introduced at Far End of Interstitial Space; ❑ Gau e; ❑ Visual Inspection; Other (Describe in J below) <br /> Vacuum was restored to operating levels inall interstitial spaces: ® Yes ❑ No (if no describe in J below <br /> J . Cornments : <br /> f <br />