My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2020 10:05:05 AM
Creation date
7/20/2020 10:41:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton , California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www. sjgov. org/ehd <br /> 111 11 111 NMI iiiiiiii I <br /> 77 <br /> lo5d , � � rc� e � # , 1rglr ,1s +l�trn 2po `t , s x <br /> Facility Flame: 1 Facility Address: � � : Date: <br /> itl00S i GO V` HOLESALE #10111 2681 REYNOLDS RANCH PKVVY, LODI May '17, 2017 <br /> xll <br /> tUs �St�x19 CI <br /> IL <br /> 323 HSC 25283. 5(a) Unburied below grade UST system failed to meet exemption status o V o R ❑ COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag o V ❑ R o COS <br /> 325 CCR 2717. 1 (f) Deposited petroleum into a red tagged UST ❑ V ❑ R o COS <br /> 326 HSC 25299(a) (9) Tampered with or disabled leak detection devices or alarms o V ❑ R o COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored o V o R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 NSC 25298 Failed to comply with permanent closure requirements a V ❑ R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V ❑ R ❑ COS <br /> rjISingle Wa1l0diI09e Pressurrlxnd ,Piping x <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V ❑ R ❑ COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe (pre�an 1984) not performed ❑ V o R o COS <br /> 403 CCR 2643(d) Triennial 0. 1 gph line test for conventional suction piping not performed (pre-January 1984) o V o R e COS <br /> 404 CCR 2643(e) Biennial 0. 1 gph test for gravity piping not performed (pre-January 1984) o V o R o COS <br /> (31�he� <br /> 2010 See below Unlisted Administration/Documentation violation ❑ V o Ro COS <br /> I 2030 See below Unlisted Operations/Maintenance violation ❑ V ❑ R ❑ COS <br /> 2060 See below Unlisted Design/Construction violation o V o R ❑ COS <br /> �� � ����. . ���€max'` ._ .«��7 .. � . r , r � ` ;� �G�.ASS{f, Ct.gBStt� otVt�NOR��IVpNa�ehaL�o"rl►I�tYi �.�,= -�' � �,�� �`��� ��.£ , �,� ,�, <br /> Item # Remarks <br /> '. 0 1 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions . <br /> Maintenance and monitoring records for the last three years were not found on site. On 05102/2017 a 323 senor I <br /> was replaced in the 87 8 fill sump. The Environmental Health Department ( EHD) was not notified as required per <br /> permit conditions. These records shall be maintained on site for at least three years . Monitoring records include : <br /> ( 1 ) date and time of all monitoring or sampling ; (2 ) monitoring equipment calibration and maintenance records ; ( 3 ) j <br /> results of any visual observations ; (4 ) results of sample analysis performed a lab or in the field ; (5 ) logs of all <br /> readings of gauges or ofhei monitoring equipment, ground Water elevations , Or other test results ; ( 6 ) results of <br /> inventory readings and reconciliations . Immediately contatr t the EF-ID to obtain a permit for the work permormed j <br /> This is a minor violation, <br /> 4i <br /> E <br /> i <br /> FA0020431 PRO535432 SC001 05/17/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.