My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
1153
>
2300 - Underground Storage Tank Program
>
PR0231413
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:58:54 PM
Creation date
7/22/2020 1:55:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231413
PE
2361
FACILITY_ID
FA0003122
FACILITY_NAME
QUIK STOP MARKET #3138
STREET_NUMBER
1153
STREET_NAME
LINCOLN
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
231-190-12
CURRENT_STATUS
01
SITE_LOCATION
1153 LINCOLN BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST INSTRUCTIONS Socket <br /> POPPET&FLOAT MOVEMENT adaptor <br /> FOR TESTABLE MODELS ONLY <br /> TOOLS NEEDED FOR TESTING: <br /> 1. 1/4"square drive extension or 3/8"square drive ex- <br /> tension with 3/8"to 1/4"socket adapter. <br /> 2. Torque wrench/1/4"or 3/8"square drive ratchet <br /> wrench. <br /> 3. Pipe dope. <br /> 4. Flashlight(optional). <br /> Open Poppet Closed Poppet <br /> TEST STEP 1: Test Figure 1 <br /> Remove spill container cover and fill cap from fill adapt- <br /> er and look down into the tube and make sure no debris Pull on extension and <br /> or foreign objects are present. If debris or foreign ob- socket adaptor <br /> jects are present take appropriate steps before proceed- <br /> ing. Look down into the tube and ensure poppet is <br /> completely protected by the deflection shield. See Test <br /> Figure 1. If poppet is exposed and tank is not full the ---- <br /> overfill valve should be replaced. A flashlight may help <br /> when inspecting the tube. r=- <br /> TEST STEP 2: v _ <br /> Unthread the socket adaptor assembly from the inlet "~ <br /> tube using a 1/4"square drive extension and wrench. I <br /> The extension will attach to the socket adaptor. Secure <br /> all tools to ensure they don't fall into the tank or valve. <br /> With the extension still attached pull on the socket <br /> adaptor and cable assembly and ensure float and pop- <br /> et move/function properly. It should only require 3" <br /> to 4"of movement and less than 5 lbs of force in order -- <br /> to actuate the float and poppet. When looking down <br /> into the upper tube ensure poppet is visible and moves <br /> into the flow path (see Test Figure 1 &2)when socket Open <br /> adaptor is pulled and resets properly when socket adap- <br /> tor is released. If poppet does not actuate freely take ', Poppet Float moves <br /> appropriate steps to correct. I � up <br /> TEST STEP 3: <br /> Apply pipe dope to the socket adaptor threads. Pipe <br /> dope should be a non-hardening gasoline resistant pipe <br /> thread seal compound. Make sure poppet and float <br /> have reset properly and are not visible then install sock- <br /> et adaptor and torque to 3.5 ft-lbs(42 in-lbs) minimum <br /> to 5.0 ft-lbs(60 in-lbs) maximum. After installing socket <br /> adaptor,to ensure vapor tightness,OPW recommends <br /> conducting pressure testing per CARB TP201.1 D. Some Test Figure 2 <br /> areas may require pressure testing of overfill valve per <br /> CARB TP201.1 D to ensure valve is vapor tight. If the <br /> drop tube fails pressure testing it may be necessary to <br /> check the seal at the poppet adaptor threads. Reinstall <br /> fill cap and spill container cover after testing. <br /> 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.