Laserfiche WebLink
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Food Program Official Inspection Report <br /> Facility Name and Address: Save Mart#12, 1431 W Yosemite Ave, MANTECA 95336 <br /> #21 Hot and Cold Potable Water Not Available <br /> OBSERVATIONS:Non adjustable hand sink, in Deli/Bakery Department, has temp at 82F. Provide 100F to 108F today. <br /> CALCODE DESCRIPTION:An adequate,protected,pressurized,potable supply of hot water and cold water shall be provided at all times. <br /> (113953(c), 114099.2(b) 114101(a), 114189, 114192, 114192.1, 114195) <br /> #27 Food Protected from Contamination <br /> OBSERVATIONS:Ware wash sink in produce prep area, has one compartment used to wash vegetables and the other <br /> compartment to wash hands. I observe employee using both compartments to wash vegetables. Stop using the hand wash <br /> compartment to wash vegetables to avoid contamination. <br /> CALCODE DESCRIPTION:All food shall be separated and protected from contamination. (113984(a,b, c,d, t), 113986, 114060, <br /> 114067(a, d,e,j), 114069(a,b), 114077, 114089.1 (c), 114143(c)) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:Back storage area walk in freezer has heavy ice condensation at the compressor pipes. Repair in 2 <br /> weeks. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Light tubes in the Dairy walk in cooler are lacking shatter proof or light boxes covers. Provide in 2 weeks. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored,served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Pipe, draining the ware wash sink in the Deli/Bakery Department, is lacking air gap. Provide air gap at <br /> least 1 inch off the floor in 1 week. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances,shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> FA0000931 PRO162365 SCO01 07/20/2020 <br /> EHD 16-23 Rev.06/30/15 Page 2 of 4 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />