2018-11-20 13:12 Sunwest Chevron 2758 >> 2094683433 P 6/15
<br /> . 1: , ,_ C
<br /> San Joaquin County
<br /> Environmental Health Department NO V 20 ZO'$
<br /> 1868 East Hazelton Avenue,Stockton, California 95205-6232
<br /> Telephone:(209)468-3420 Fax_(209)468-3433 Web:w".,sigov.orWehd
<br /> }"
<br /> Underground Storage,Tank Program Inspection Reportr . :.��n►_:
<br /> FacilityName: Facility Address: Dale_
<br /> Sunwest Chevron 275$W Kettleman Ln Lodi October 17 2018
<br /> SUMMARY OF VIOLATIONS
<br /> {CLASS I,CLASS U,or MINOR-Notice to Comply)
<br /> Hem# Remarks
<br /> 313 HSC 25290.1,25290.2, 25291 Failure to construct,operate,and maintain primary containment as product-tight.
<br /> Oily liquid was observed in UDCs 314, 718, 9110, 11/12,and 13114, indicating a leak in the primary piping. All primary
<br /> containment for the UST system must be tight. Immediately have a properly licensed,trained,and certified contractor
<br /> repair or replace the failed component under permit and inspection of the EHD.
<br /> This is a minor violation_
<br /> 314 HSC 25290.1,25290.2, 25291 Failed to have secondary containment or secondary containment hot fight.
<br /> Brine was found in the bottom of the diesel STP sump, 91 STP sump, diesel rill sump,87 fill sump,and 91 fill sump,
<br /> indicating a leak in the secondary containment. Secondary containmcnl shall be impervious to the liquid and vapor of
<br /> the substance contained and constructed to prevent structural weakening as a result of contact with any hazardous
<br /> substances released from the primary containment, Immediately contact a properly licensed,trained, and certified
<br /> contractor to make repairs to the UST System under permit and inspection of the EHD.
<br /> This is a minor violation,
<br /> 319 CCR 2635,2637.1,2665, 2712 No spill bucket,failed to contain 5 gallons,no means to keep it empty,or failed to be
<br /> tested.
<br /> The diesel spill container failed when tested. Ail spill containers shall have a minimum capacity of five gallons and be
<br /> capable of containing a spill or overfill until it is detected cr cleaned up. Immediately contact a properly licensed,
<br /> trained, and certified contractor to repair or replace the spill container under permit and inspection of the END.
<br /> This is a minor violation. �y� Q-r'3 4
<br /> Overall Inspection Comments,
<br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement
<br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting
<br /> paperwork, by November 29, 2018,
<br /> Note: The full inspection was not witnessed. Testing of sensor functionality, sensor out,fail safe, spill buckets,
<br /> and leak detectors was not witnessed. Vacuum communication, brine communication, and overfill prevention
<br /> testing were all witnessed. The monitoring system certification was conducted on October 17, 2018, The
<br /> paperwork inspection was completed an October 30, 2018.
<br /> Starting September 1, 2018, all in-office CORS help will be provided at EHD hourly rate ($152). To schedule an
<br /> appointment, please call (209)468-3420.
<br /> Documents provided: Return to Compliance Certification form, schedule of free CUPA classes, blank financial
<br /> responsibility documents, recordable release form, new owner/operator compliance statement and statement of
<br /> designated operator forms
<br /> FA0023733 PRMA1416 %(-DDI 1 01 1 7120 1 8
<br /> EHD 23-01 Rev.09/22/16 Page a of 9 Undergrouna Storage Yank P"Men OIR
<br />
|