Laserfiche WebLink
2018-11-20 13:11 Sunwest Chevron 2758 >> 2094683433 ' J7 ?a5 5 <br /> San Joaquin County 0 2018 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton.California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)4683433 Web:www.sjgov,org/ehd <br /> i' <br /> Underground Storage.Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Sunwest Chevron 2758 W Kettleman Ln, Lodi October 17 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 211 CCR 2715(c)(2)No employee present that were trained in the operation and maintenance of the UST system by a DC. <br /> The designated operator employee training for Dara Peralta and Perla Herrera was not performed within 30 days of <br /> hire. Neither had training at the time of the monitoring system certification on 10/17/18. According the to the training <br /> records dated 10/18/18, Ms, Peraita began as a facility employee in February 2018 and Ms. Herrera began as a <br /> facility employee in May 2018. The designated operator shall train facility employees for which he or she is <br /> responsible in the proper operation and maintenance of the UST system once every 12 months, The training shall <br /> include, but is not limited to- <br /> 1.Operation <br /> o:1.Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have bccn trained by the designated operator,maintain the list on site,and submit a Cop of <br /> the training records to the EHO.� � W 0,n3 0.� 114V � ,� � �� Y7 � <br /> This is a r peat violation. Class I1. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The brine in the following sump secondary containment was observed to be low,with no brine in the reservoirs and the <br /> tubes attaching the reservoir to the sump wall partially empty: <br /> -Diesel STP sump <br /> -91 STP sump <br /> -Diesel fill sump <br /> -91 fill sump <br /> -87 fill sump <br /> -Vent sump <br /> The L2 (87 fill sump), L3(91 STP sump), L5(diesel STP sump),and L6 (diesel fill sump)sensors were all in Low <br /> Liquid Alarm upon arrival. <br /> The sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach in the primary or <br /> secondary containment is detected before the hazardous substance is released into the environment. The brine levels <br /> were topped off during the inspection_ <br /> This is a minor violation. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The L2(87 fill sump),L3(91 STP sump),i_5(diesel STP sump),and L6(diesel fill sump)sensors were found to be in <br /> Low Liquid Alarm since 10/10/18(1_2&1-5), 10/14/18(1-6), and 10/15/18(1-3), and actions have not been taken to <br /> address the alarm. Mr. Prasad stated that it is a new system and the alarms either clear themselves or are due to <br /> settling_ He stated there are no leaks in the system and was unaware of the brine observed in the fill and STP sump <br /> bollorns. All monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br /> The brine levels were topped off and the alarms were cleared at the time of inspection, <br /> This is a Class 11 violation. <br /> FAD023733 PRDS41419 SCO01 10117/2018 <br /> EHD 2301 Rev.09=116 Page 7 of 9 Underground Storage Tank Program OIR <br />