Laserfiche WebLink
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: MG WATERSTONE APARTMENTS LP, 1951 W MIDDLEFIELD DR, TRACY 95377 <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool lights are currently not functioning but the pool deck contains lights on the outskirts of the pool. <br /> Maintenance stated that the lights turn on every night. Repair lights inside of pool or disconnect and have a certified <br /> electrician state that power is no longer being provided to the light fixtures. Correct immediately. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The handrail to enter the spa, on the right hand side, is currently loose.Tighten and secure before <br /> operation. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter is currently placed in a location in which it can not be observed. It is uncertain if the flow <br /> meter is functioning, broken or stuck.Advise to place a flow meter in a location in which it can be easily monitored. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The influent gauge is currently broken due to the needle displaying 0 while the pump was in operation. <br /> Repair or replace before next routine inspection. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 2.8 ppm Temp: 90.00 ° F <br /> Cyanuric acid: 90 ppm pH: < 7.0 Combined chlorine: 0.2 ppm <br /> NOTES <br /> FA0017844 PR0526368 SCO01 06/25/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />