My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1988
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
230
>
2300 - Underground Storage Tank Program
>
PR0231330
>
INSTALL_1988
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 8:55:32 AM
Creation date
7/23/2020 12:02:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1988
RECORD_ID
PR0231330
PE
2361
FACILITY_ID
FA0003964
FACILITY_NAME
LODI PUBLIC SAFETY BUILDING
STREET_NUMBER
230
Direction
W
STREET_NAME
ELM
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04303109
CURRENT_STATUS
02
SITE_LOCATION
230 W ELM ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 9 of 13 <br /> C. BONDING AND ADHESIVES SYSTIIVlb (Fiberglass Pipe) : (CONTINUED) <br /> 3. Inspect all fittings forro <br /> joints. P P ' alignment and possible "back-out" at the <br /> 4. Follow pipe manufacturer's re _ndations on cure time before disturbing joints <br /> or testing. In areas of temperature below 60 degrees F 16 <br /> be necessary to apply heat for curing adhesive. Only kcal ooelC� rical <br /> devices recommended by Pipe manufacturer are acceptable for this purpose. No <br /> open flame or sparkling devices are to be used. <br /> D. THREADED JOIN'T'S <br /> 1. Threaded joints must be reamed and have clean cut, perfect threads and be made <br /> up with non-hardening joint compound insoluble in <br /> Company Representative. petroleum products approved by <br /> 2. Approved joint C pound: <br /> Rectorseal <br /> Gilbarco Pipe Joint Compound <br /> Permatex 57 <br /> E. FIBERGLASS TO STEEL PIPE C=NU CYTONS: Fiberglass threaded-errs adapters are to be <br /> threaded into the steel pipe or fitting before bonding onto the fiberglass pipe. <br /> F. SWING JOINTS: Use steel pipe and fittings: two 90 degree elbows with nipple <br /> connection (do not use close nipple or street ell) at vent risers only. <br /> G. FLMBLE OONNECTIORS: Use flexible connectors for connection of product and vapor <br /> return piping at tanks and dispensers, and for vent piping at tanks. <br /> H. SPECIAL, FITTTNGS: <br /> 1. The shut-off valve ("Shear" or "Safety" valve) at the base of the product pump <br /> or dispenser is to be secured in position with a steel stabilizer as detailed on <br /> the drawings. <br /> 2. Position the valve so that the line test port plug is acoessible. <br /> PIPE WRAPPING: All underground steel pipe and fitti,;gs shall be field primed and <br /> wrapped. Wrapping material shall be 35 mil polyethylene tape "polyken 930" <br /> manuf4 acturered by the Kendall Ccnpany (or equal approved by C=rpany Representative) . <br /> Wrap overlap shall be one-half width of wrapping material. Wrap 1-1/2" and 2" <br /> fittings with Polyken 900 (12 mils) with a 60% overlap. In difficult areas Polyken <br /> 931 can be used before wrapping with Polyken 900. Primer shall be Polyken 927. <br /> J. SETTING AND BEDDING PIPE: <br /> 1. A 4" minimum bed of backfill material is to be placed in all piping <br /> trenches. Smooth, compact and slope bedding material to allow a slope of 1/4" <br /> per foot toward the tanks. In extreme conditions, 1/8" per foot may be used if <br /> approved by Owner's Representative, refer to other portions of these <br /> specifications. <br /> 2. Piping shall be placed on prepared bed in such a manner as to minimize points at <br /> which one pipe may cross over another pipe. At points where piping must cross <br /> aver, a minimum of one pipe diameter must separate the pipes. <br /> 6.20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.