Laserfiche WebLink
2.0 INFORMATION ON DRINKING WATER WELL DESIGN <br /> 2.1 Welenco Video Survey <br /> A video survey was completed to gather additional information regarding construction and design <br /> of the drinking water well located at Franks One Stop, 2072 W Yosenute Avenue, Manteca, <br /> California On November 25, 1997, Welenco removed the pump and piping from inside the well <br /> A video survey was then completed using the top of casing as the datum The results of the video <br /> survey are summarized on the Welenco report presented in Appendix A <br /> The inside diameter (ID) of the well at the surface was shown to be 8 inches diameter Screened <br /> intervals were reported from 84 to 102 feet, 104 to 121 feet, and 123 feet to bottom of survey <br /> (140 feet) The static water level was reported at 16 feet <br /> 2.2 Additional Well Design Data <br /> A well permit for construction of the drinkingwater well located at Franks One Stop in <br /> p Manteca <br /> is on file at San Joaquin County The permit (#1286) is recorded under Hunter Travel Service - <br /> Ed Ramsey (the well address is given as 4022 E Hwy 120) <br /> Hennings Bros Drilling Co , of Modesto, California installed the well in 1978 Their well <br /> drillers report indicates that the well is 8 inches in diameter and a total depth of 145 feet The <br /> perforations are from 85 ft to 145 ft Standing water was reported at a depth of 17 feet No well <br /> tests were completed at the time of construction <br /> I <br /> Remedy Inc, Report of Quarterly Sampling ofDrrnkrrrg Water Well August 28, ]99S <br /> Frank's One Stop, 2072 W Ynsemrte Avenue Manteca, CA 01 SQ398 RP7 <br /> 3 <br />