My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUCKLEY COVE
>
4950
>
2300 - Underground Storage Tank Program
>
PR0231028
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 1:56:26 PM
Creation date
7/27/2020 2:43:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231028
PE
2361
FACILITY_ID
FA0003811
FACILITY_NAME
RIVER POINT LANDING MARINA-RESORT*
STREET_NUMBER
4950
STREET_NAME
BUCKLEY COVE
STREET_TYPE
WAY
City
STOCKTON
Zip
95219
APN
11820001
CURRENT_STATUS
01
SITE_LOCATION
4950 BUCKLEY COVE WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.s'gov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RIVER POINT LANDING MARINA-RESORT* 4950 BUCKLEY COVE WAY, STOCKTON January 24, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3) "Designated Underground Storage Tank Operator Identification Form" not submitted <br /> within 30 days. <br /> Zane Nimmo performed the designated operator inspections on 5/4/18 and 11/27/18. Mr. Nimmo is not listed on the <br /> site's list of designated operators and notification was not provided to the EHD within 30 days of the change. Any <br /> changes shall be reported to the EHD within 30 days. Immediately log into the California Environmental Reporting <br /> System(CERS) at http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for <br /> this facility. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> A designated operator inspection was performed on October 24, 2018 and the next inspection was performed on <br /> November 27, 2018, 34 days later. The designated operator visual inspections shall be conducted within 30 days or <br /> less of the previous inspection. Ensure that all designated operator inspections are performed within the required <br /> time frames. <br /> The designated operator failed to check and note all required items on the visual inspection reports. <br /> -The 10/24/18 inspection report left blank the question regarding UDC sensor locations. <br /> -The 11/27/18 inspection report left blank the tank tightness testing information. <br /> -The 12/13/18 inspection report incorrectly marked overfill prevention testing as 'no.' <br /> -The 10/24/18, 11/27/18, and 12/13/18 inspection reports did not include the 'N' and 'NA' items in Section III. <br /> -Section V of the 1/11/19 inspection report was left blank. <br /> -The 10/24/18, 11/27/18, 12/13/18, and 1/11/19 inspection reports were not signed by the owner/operator. <br /> During the visual inspection, the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and shall check all required items on the report. Ensure that designated <br /> operators performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. The <br /> underground storage tank system shall be operated to prevent unauthorized releases. Immediately provide <br /> approved secondary containment for the filters under permit and inspection by the EHD. <br /> This is a Class II violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. Secondary <br /> containment shall be provided for all single-walled UST components. Immediately provide approved secondary <br /> containment for the filters under permit and inspection by the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0003811 PR0231028 SCO01 01/24/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.