My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2020 4:52:48 PM
Creation date
7/29/2020 8:24:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fn <br /> O <br /> 7 i � UIN <br /> Environmental Health Department <br /> iCavNTY p ent <br /> 119 Z$ <br /> Program Inspection a .o <br /> ?F&C'M Name:AN DE POL ENT INC/PACIFIC PRIDE Facility Address: <br /> 351 N BECKMAN RD LODI <br /> Date <br /> Ah r ISL r y June 26 2019 <br /> Item# <br /> 201 Remarks id-w- OWN <br /> CCR 2712(b)(1-2) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. Maintenance records for L2-91 <br /> fill fuel alarm on 11/30/18, L8-87 STP fuel alarm on 12/17/18 and L6-Red diesel fuel alarm on 1/11/19 were not <br /> found on site. the monitoring plan for all tanks state yes under record keeping for Tank integrity testing, SIR testing, <br /> Tank gauging, ATG testing, and corrosion protection logs, however these records were not found on site,when the <br /> maintenance supervisor was asked if for the records, he was not able to provide them to the inspector.These <br /> records shalLbe maintained-on-site-for atJeast-three years._Monitoring records include:(1)date and time of all <br /> monitoring or sampling; (2)monitoring equipmerif calibration and maintenance records;(3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results;(6)results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a repeat violation, Class II. n n <br /> 202 CCR 2715(c)(3),2715(c)(4)Failure t <br /> 2018). o maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> "Facility Em aining Certificate"dated 12/10/19 was found on site stating that employee, Ronnie Ignacio was <br /> trained o 12/10/ onnie Ignacio'date of assuming responsibility is stated as 11/20/19 however the initial training <br /> date was stated to be 12/10/19 both of which dates are in the future,ensure the DO is writing correct dates under <br /> the"Facility Employee Training Certificate".All site employees must be trained prior to taking responsibility as a <br /> facility employee if after October 1, 2018,or within 30 days of hire if prior to October 1,2018.The"Facility <br /> Employee Training Certificate"shall contain accurate information for all employees trained. Update the"Facility <br /> Employee Training Certificate"to contain the accurate information and submit a copy of the updated form to the <br /> EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans-were not available-for-inspection. A copy of these plans shall be <br /> ./ accessible on site at all times. Immediately locate and retain a copy on site.' <br /> This is a repeat violation, Class If. <br /> P�. ,- <br /> 205 CCR 2712(i),2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br /> An approved copy of the response plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> N <br /> This is a repeat violation, Class II. <br /> ?t 4N 4—� T N <br /> FA0=778 PROW= SC001 U6t7612019 <br /> EHO 23.01 Rev,09)28/2018 Pape b of 8 Underground Storaga Tank P.W01 GM <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468.34201 F 209 464-0138 ( www. (*hd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.