Laserfiche WebLink
3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified at the Project Site: Presently,there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence <br /> of buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> County Records indicated there were no fuel tanks on site. There were no above ground fuel tanks <br /> on the site at the time site survey was performed on May 26, 2020. On-site storm water dissipates <br /> through either percolation or evaporation. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified In the Area of the Project Site: Past off-site potential <br /> for contamination is low. The land use has historically been residential and grazing and has not <br /> changed significantly. The neighboring parcels are also used for rural residential and agricultural <br /> purposes. There are no activities taking place in the site's proximity that could be a source of <br /> contamination. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project Site: Present off-site potential <br /> for contamination is low. There are no identified sources that could be a cause for potential <br /> contamination. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of each potential and/or known source of contamination identified for any real <br /> and/or potential threat to human health and the environment: The depth to ground water in this <br /> area is approximately 130 feet. Due to this depth, any pesticides, insecticides, and fertilizers used <br /> on the property in the past or present would have a minimal impact to the ground water. No further <br /> actions are recommended at this time. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers or fuel storage tanks <br /> on this site. Thus the potential for contamination is low. There are no pesticides,insecticides, and <br /> fertilizers used on the site. No mitigation measures are recommended. <br /> 5.2 The report is inclusive: All information in this report does not reference any other documents <br /> that are not contained in this report. <br /> 5.3 Report was signed dated and stamped: See below. <br /> 5.4 The report was prepared within Six Months of the Date of the Submittal: This report was <br /> originally generated in May, 2020. <br /> 5.5 The Aitachmeut/Appendices Contain Sufficient Documentation to Support Claims Made <br /> in Report: See Appendix. <br />