Wastewater Discharge Permit, City of Lodi Number 427A <br /> Page 3 <br /> MONITORING REQUIREMENTS(Continued) <br /> Sample Measurement <br /> Parameter Location Freauencv Sample Type <br /> Lead Stages(2,4 and 7), Twice Yearly, Grab <br /> Stages(1,3,5, and 8)2 Each Discharge2 Grab <br /> Industrial Sewer Manhole3 Twice Yearly3 Composite <br /> Nickel Stages(2,4 and 7), Twice Yearly, Grab <br /> Stages(1,3,5, and 8)2 Each Discharge2 Grab <br /> Industrial Sewer Manhole3 Twice Yearly3 Composite <br /> Silver Stages(2,4 and 7), Twice Yearly, Grab <br /> Stages(1,3,5, and 8)2 Each Discharge2 Grab <br /> Industrial Sewer Manhole3 Twice Yearly3 Composite <br /> Zinc Stages(2,4 and 7), Twice Yearly, Grab <br /> Stages(1,3,5, and 8)2 Each Discharge2 Grab <br /> Industrial Sewer Manhole3 Twice Yearly3 Composite <br /> TTO' Stages(2, 4 and 7), Twice Yearly, Grab <br /> Stages(1,3,5 and 8)2 Each Discharge2 Grab <br /> Industrial Sewer Manhole3 Twice Yearly3 Grab <br /> TTO Total Toxic Organics by EPA method 624,625 and 608. <br /> 1.Samples of batch discharges must be taken an analyzed at least once between January and May and once between July and November. <br /> 2.Samples must be taken an analyzed at each batch discharge. <br /> 3.Samples of continuous discharge must be taken an analyzed at least once between January and May and once between July and November. <br /> B. The City must be notified and re-sampling is required within 24 hours of noticing any slug load, spill or effluent <br /> violations to the sewer system. The results from re-sampling must be submitted to the City of Lodi within 30 days of <br /> the slug load, spill or effluent violation. <br /> C. All handling and preservation of collected samples and laboratory analyses of samples shall be performed in <br /> accordance with 40 CFR Part 136 and amendments thereto by a State certified laboratory unless specified otherwise <br /> in the monitoring conditions of the permit. <br /> PART 3-NOTIFICATION REQUIREMENTS <br /> A. The permittee may allow any bypass to occur which does not cause Pretreatment Standards or Discharge <br /> Requirements to be violated, but only if it also is for essential maintenance to assure efficient operation. These <br /> bypasses are not subject to the provisions of(B)and(D)of this section. <br /> B. If the permittee knows in advance of the need for a bypass, it shall submit prior notice to the City, if possible at <br /> least ten days before the date of the bypass. <br /> C. The permittee shall provide telephone notification of an unanticipated bypass that exceeds applicable Pretreatment <br /> Standards to the City within 24 hours from the time the permittee becomes aware of the bypass. A written <br /> submission shall also be provided within 5 days of the time the permittee becomes aware of the bypass. The written <br /> submission shall contain a description of the bypass and its cause; the duration of the bypass, including exact dates <br /> and times, and, if the bypass has not been corrected, the anticipated time it is expected to continue; and steps taken <br /> or planned to reduce, eliminate, and prevent reoccurrence of the bypass. The City may waive the written report on a <br /> case-by-case basis if the telephone notification has been received within 24 hours. <br /> D. Intentional diversion of wastestreams from any portion of the permittee's treatment facility, bypass, is prohibited, <br /> and the City may take enforcement action against the permittee for a bypass, unless; <br /> 1. Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage; <br /> (Continued next page) <br /> C:\Lab Files\permits\427AThule.doc <br />