SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PARKWOODS GAS & FOOD 1612 W HAMMER LN STOCKTON May 08 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. <br /> -The Certification of Financial Responsibility form is dated 5/19/17. <br /> -The Letter from the CFO has asset and liability amounts that have not been updated since 2015. <br /> Current financial responsibility documents are required to be submitted annually. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class II. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information form for the 87 tank is not current in CERS. <br /> -The 87 tank form incorrectly states the riser piping is fiberglass; the risers on site are all steel. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring plans for all three tanks incorrectly state monitoring equipment service is performed "quaterly". The <br /> site conducts annual monitoring equipment service. <br /> -The monitoring plans for all three tanks list the mechanical leak detector manufacturer under both the manufacturer <br /> and the model sections. <br /> -The monitoring plans for all three tanks incorrectly state the monitoring panel is a Veeder-Root TLS-350 under tank, <br /> piping, and UDC monitoring. The monitoring panel on site is a Gilbarco EMC. <br /> -The monitoring plans for the 91 and diesel tanks left blank the question regarding UDC sensor failure/disconnection. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. <br /> -The map did not include the locations of piping. <br /> A site plan must be submitted identifying the locations where monitoring will be performed. Immediately log into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a minor violation. <br /> FA0003611 PR0231127 SCO01 05/08/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />