GENERAL NOTES <br /> I'- <br /> Z <br /> W <br /> 1 ALL VACUUM TUBING MUST BE VEEDER ROOT <br /> APPROVED VACUUM TUBING. <br /> � o <br /> 2 AN EXTERNAL SIPHON CHECK VALVE(VEEDER <br /> ROOT#3188.241-5)MUST BE USED WHEN MAKING W <br /> A VACUUM SOURCE CONNECTION BETWEEN j <br /> SVCS SYSTEM SENSORS AND THE SIPHON PORT 0 <br /> CARTRIDGE FOR ALL TURBINES. ly <br /> Iy <br /> W <br /> 3 ALL PENETRATIONS THROUGH TANK SUMPS, <br /> � <br /> UDC SUMPS AND VENT SUMPS TO BE MADE BY A <br /> QUALIFIED CONTRACTOR. 0) <br /> N <br /> 4 ALL CONTAINMENT SUMPS TO BE INSTALLED <br /> PER THE MANUFACTURER'S INSTALLATION N <br /> INSTRUCTIONS. <br /> 5 ALL CONDUIT PENETRATIONS AND J-BOXES TO <br /> BE INSTALLED ABOVE FUEL LINE PENETRATIONS. <br /> 6 CONTRACTOR SHALL POSITION LIQUID ONLY Proto 11-05-18 <br /> SUMP SENSORS AT SUMP LOW POINT ON SIDE <br /> CLOSEST TO PRODUCT PIPING. <br /> M <br /> ti3 <br /> p <br /> Lo <br /> = J <br /> PRESSURE SENSOR AND U ~ 00 Lc) <br /> � '- <br /> ASSOCIATED EQUIPMENT ONLY z w Q N U H <br /> REQUIRED AT DISPENSER#5 FILL > " 3! W W <br /> 1 Z ZO U F — U <br /> W Q z u) O Z <br /> WRAP RUBBER SHIM FROM KIT DISPENSER V BALL VALVE BY GC W w > 3: � O <br /> AROUND SENSOR BEFORE UNION AND 1" PIPE FITTINGS BY GC VENT _I � W © OU W I-- <br /> INSERTING INTO CLAMP ESD FLOW METER <br /> PRESSURE SENSING POINT (SUPPLIED WITH DISPENSERS) STP W Lu J co w p <br /> 114"OD COPPER TUBE J-BOX AND CORD GRIPS BY GC WITH 1-112"X 111 3 �' Y 1 W 2 <br /> BRASS BUSHING AND __,._._. U PI > <br /> PITCH TO DRAIN 114"VERTICAL I ELEC SEAL OFF BY GC 1/4" BRASS BARB ATG 31 3-ZONE Q <br /> PER 12"HORIZONTAL FITTING BY GC VACUUM KIT <br /> - Q <br /> N <br /> a ° ao STP POWER CONDUIT SENSOR CONDUIT DSLVENT SENSOR CONDUITPIPING <br /> 3-WAY 114"BALL VALVE CONDUIT TO TLS CONSOLE <br /> FLOW METER AND PRESSURE SENSORWIRING CAN SHARE THE SAME CONDUIT PRODUCT PIPING VACUUM PIPING <br /> TO CONSOLE (OBSERVE POLARITY)STAINLESS STEEL FLEX CONNECTOR <br /> JJA 2"BLACK IRON PIPE4"a AND FITTINGSBY GC <br /> L;WITH 1-112"X 114" <br /> UDcLIQUID ONLY SENSOR AND LIQUID ONLY SENSOR <br /> PIPING AND FITTINGS <br /> 90 FRP VAPOR RETURN LINE B4�' BRASS BARB <br /> VEEDER ROOT FITTING BY GC <br /> VACUUM TUBING <br /> VENT BOX VACUUM VAPOR FLOW METER VACUUM ZONES 7 , 8 AND 9 Z <br /> SENSOR DETAIL DIAGRAM AT DISPENSERS AT TANK 3 ( DIESEL) 0Lid <br /> 5 N.T.S. N.T.S. 3/4"=1'-0" s <br /> 4 <br /> a <br /> w <br /> ILL <br /> Z <br /> L7 u1 m <br /> 1 71 <br /> W � w n <br /> z o <br /> ..� <br /> w <br /> C) J J <br /> J� <br /> � pis U Z a <br /> w 614 w <N <br /> x I <br /> w a <br /> w <br /> 0 <br /> c� <br /> Flo4 <br /> F.W. © Z I- <br /> O <br /> VAPOR FILL Z N <br /> Q � m <br /> L�] N <br /> co <br /> E p U i <br /> ­5 f!) ❑ ❑ U <br /> STP STP <br /> j IMTH 1-112"X 114" 3o <br /> o 3 <br /> c <br /> BRASS BUSHING AND --- BRASS BUSHING AND -- - -- y � w o 3 0 <br /> c � Nu�•- <br /> 114"BRASS BARB ATG 31 -ZONEL 114"BRASS BARB ATG 31 3-ZONE o o a E �, 2 c <br /> FITTING BY GC VACUUM KIT __ FITTING BY GC VACUUM KIT ¢ o o� c y o o Ch ar <br /> p TO RUL&PUL <br /> VENT PIPING& ++ � � �U.N � �� � �� O E <br /> TO VAPOR ++ �y M 01E c O +: S vi•- <br /> STP POWER CONDUIT SENSOR CONDUIT v NT suMP SENSOR CONDUIT STP POWER CONDUIT SENSOR CONDUIT INTERSTITIAL SENSOR CONDUIT m Q� 3 (D >,:3% 3°3 aCi a <br /> &DISP SUMPS 6 � L�D O O N .0 — <br /> ° 56 ° 1 23 ° ° G� Q1Nc3W � G3UN <br /> L� N 2 CA 7+N+�+ C•�_lQ l3 <br /> N GY 7Q•� ^C� {r7io-. 2 <br /> T PIPINGVACUUM PIPING PRODUCT PIPING VACUUM PIPING o - <br /> PRODUC <br /> Q. <br /> L U L !n -�•(� H•- <br /> o 0 aN-O (D QN= O_� <br /> € _ ❑Q r co <br /> O <br /> _ (02Off ' O N <br /> a � <br /> o0 <br /> 0�g�QF,I:SS1 <br /> WITH 1-112"X 114" 3 WITH 1-112"X 114" 35 UID ONLY SENSOR <br /> LIQUID ONLY SENSOR BRASS BUSHING AND LIQUID ONLY SENSOR LIQUID ONLY SENSOR BRASS BUSHING AND LIQUID <br /> 0 114"BRASS BARB 114"BRASS BARB _cj <br /> FITTING BY GC FITTING BY GC 35558 <br /> 4iFCH NWGQ�. <br /> T�Ofi CA4WF0� <br /> VACUUM ZONES 4, 5 <br /> AND 6 VACUUM ZONE 1 2 AND 3 SHEET: 12118/19 <br /> AT TANK 2 ( PREMIUM UNLEADED AT TANK REGULAR UNLEADEDG 12 . 2 <br /> z 2 3/4"=1'-0" <br /> 3/4"=i'-O" <br /> FUELING - USA CA <br />