Laserfiche WebLink
GENERAL NOTES <br /> 1 ALL VACUUM TUBING MUST BE VEEDER ROOT <br /> APPROVED VACUUM TUBING. U) U) U) <br /> 3 <br /> 2 AN EXTERNAL SIPHON CHECK VALVE (VEEDER Z Z Z� <br /> ROOT#3188-241-5) MUST BE USED WHEN MAKING W W W <br /> A VACUUM SOURCE SENSORS AND THE SIPHON L <br /> cn 2 <br /> PORT CARTRIDGE FOR ALL TURBINES. � O O O <br /> U U U <br /> TEST PORT TEST PORT <br /> 3 ALL PENETRATIONS THROUGH TANKS SUMPS, <br /> STP STP UDC SUMPS AND VENT SUMPS TO BE MADE BY A U U U <br /> WITH 1-1/2"X 1/4" 35 WITH 1-1/2"X 1/4" 35 QUALIFIED CONTRACTOR. <br /> 0 0 0 <br /> BRASS BUSHING AND BRASS BUSHING AND <br /> 4 ALL CONTAINMENT SUMPS TO BE INSTALLED PER <br /> 1/4" BRASS BARB ATG 31 3-ZONE 1/4" BRASS BARB ATG 31 3-ZONE THE MANUFACTURERS INSTALLATION cu o o N <br /> FITTING BY GC ° VACUUM KIT FITTING BY GC ° VACUUM KIT INSTRUCTIONS. 0 0 0 <br /> 5 ALL CONDUIT PENETRATIONS AND J-BOXES TO <br /> STP POWER CONDUIT SENSOR CONDUIT STP POWER CONDUIT SENSOR CONDUIT BE INSTALLED ABOVE FUEL LINE PENETRATIONS. > aaa <br /> ° ° 7 8 9 ° ° ° ° -7oln 1 2 3 ° ° ° 6 CONTRACTOR SHALL POSITION LIQUID ONLY <br /> PRZ77z <br /> VACUUM PIPING PRODUCT PIPING VACUUM PIPING SUMP SENSORS AT SUMP LOW POINT ON SIDE Proto 11-05-18 <br /> ° ° ° ° ° ° ° ° ° ° CLOSEST TO PRODUCT PIPING. <br /> I I *mom[ <br /> 02 03 03 02 02 03 <br /> 90 TYP 90 TYP <br /> FBI KEY NOTES co <br /> c� <br /> TEST PORT NOTE: TEST PORT NOTE: o <br /> Lo <br /> LIQUID ONLY SENSOR VACUUM KIT TO BE MOUNTED TO IQUID ONLY SENSOR VACUUM KIT TO BE MOUNTED TO r- <br /> ATG RISER. <br /> ATG RISER. � ELECTRICAL CONDUIT(S)TO ENTER SUMP 2" MIN <br /> REF SHEET G12.2 FOR ADDITIONAL REF SHEET G12.2 FOR ADDITIONAL ABOVE HIGHEST PRODUCT PENETRATION. X P" <br /> SUMP SECTION (FOR VACUUM ZONES INFORMATION SUMP SECTION (FOR VACUUM ZONES INFORMATION W 1 U) <br /> AND DETAILS. AND DETAILS. LOCATE ELECTRICAL JUNCTION BOX IN UPWARD ~ H J <br /> VACUUM ONLY VACUUM ONLY POSITION AT HIGHEST LOCATION IN SUMP RISER Z Z LLI W � Q <br /> MA T IN "T 10" CL FOR EASY ACCESS FROM ABOVE. — � <br /> FROM TOP OF MANHOLE COVER MAINTAIN 8"TO 10"CLR - � Q W <br /> 19 TO TOP OF WT COVER 19 FROM TOP OF MANHOLE COVER �3 SUMP SENSOR TO REST AT LOWEST POINT OF Z — � U D <br /> TO TOP OF WT COVER SUMP ENCLOSURE ON PRODUCT PIPING SIDE OF 0 Z 0- O <br /> 4 WATERTIGHT COVER WITH 4 w Q < 0<Z <br /> OBSERVATION PORT WATERTIGHT COVER WITH SUMP. TANK CONTRACTOR TO SUPPLY ALL > O < W <br /> 20 20 OBSERVATION PORT BRACKETS AND CLAMPS FOR 2-POINT MOUNTING H J <br /> CONCRETE TANK SLAB o D ALIGN PORT WITH ATG CONCRETE TANK SLAB a s a J U Y z <br /> , - a a a <br /> ALIGN PORT WITH ATG OF THE 2" FRP SLEEVE. w W Y Cn CD <br /> TRIM MH SKIRT TO MAINTAIN 2"TO 4" <br /> 01 01 a a TRIM MH SKIRT TO MAINTAIN O <br /> o , BETWEEN SUMP SECURE FOAM PIPE ® SET MANHOLE COVERS 1"ABOVE THE FINISH W � L H Z <br /> 2"TO 4" BETWEEN SUMP <br /> INSULATION TO BOTTOM OF MH SKIRT. 10 GRADE AND SLOPE CONCRETE AWAY FROM w W 0 Q <br /> o SECURE FOAM PIPE INSULATION m <br /> p p ADD INSULATION AS REQUIRED TO 4 da TO BOTTOM OF MH SKIRT MANWAY COVERS AT 2% GRADE. Y 1 <br /> 2 > PREVENT CONCRETE FROM BEING POURED 2 U <br /> EXPLOSION PROOF o ON SEALED MANHOLE EXPLOSION PROOF 2 EXPLOSION PROOF J-BOX POSITION BALL VALVE FOR UNOBSTRUCTED USE Q <br /> J-BOX TYP (POWER) J-BOX TYP (POWER) _ <br /> 2 EXPLOSION PROOF J-BOX ELEC SEAL-OF (FOR SENSORS) OF SHUT-OFF HANDLE. <br /> ELEC SEAL-OFF C) <br /> ' (FOR SENSORS) � E N <br /> 5 30 5 30 © STP POWER CONDUITS MUST BE RUN IN co <br /> m m E m m 2"SCHED 40 GALV PIPE FITTINGS SEPARATE RACEWAY. ENTIRE WIRING RUN MUST <br /> ELEC SEAL-OFF CONDUIT AND LBY'S TO 6 FOR REGULAR AND PREMIUM BE IN RIGID PVC COATED GALVANIZED STEEL <br /> CONDUIT AND LBY'S TO 6 STP POWER CONNECTION BY GC CONDUIT. USE ONLY ROB ROY CONDUIT TYPES <br /> STP POWER CONNECTION 7 CONDUIT FROM ANNULAR SPACE CONDUIT FROM ELEC ROOM 6 ELEC SEAL-OFF "PERMA-COAT", "PLASTI-BOND" OR"KORKAP", NO <br /> CONDUIT FROM ELEC 6 MANHOLE FOR SENSORS FOR STP POWER PVC OR RNC CONDUIT ALLOWED. <br /> 1 7 7 CONDUIT FROM ANNULAR SPACE <br /> ROOM FOR STP POWER 6 1 MANHOLE FOR SENSORS ❑7 USE ONLY ROB ROY CONDUIT TYPES <br /> REF 5-G4.1 <br /> ° ° ° FUEL PLUMBING TREE XERXES DW SUMP SUPPLIE ° ° ° ° "PERMA-COAT", "PLASTI-BOND" OR"KORKAP" <br /> 1 1 7 <br /> w/TANKS (TYP) ELECTRICAL CONDUITS AT FIBERGLASS TANK <br /> QO ° ° ° ° 06 ° ° ° FUEL PIPING TREE SUMPS OR WHERE BRAVO F-17-RR OR F-10-RR <br /> 2" SCHED 40 BLACK IRON 15A° GO Q0 ° REF 5-G4.1 ENTRY FITTINGS ARE CALLED OUT. <br /> PIPE FITTINGS FOR 2" SCHED 40 GALVANIZED 06 <br /> DIESEL BY GC SUMP SENSOR BRACKET PIPE FITTINGS FOR REGULAR <br /> U-BOLTED TO ATG RISER (2 LOC) AND PREMIUM BY GC GO <br /> 2" FRP X 33" LONG MIN 03 PIPE CLAMPS, SENSOR BRACKETS 2" FRP X 33" LONG MIN 03 SUMP SENSOR BRACKET W <br /> (BEYOND) FOR SUMP SENSOR AND U-BOLTS BY GC (BEYOND) FOR SUMP SENSOR U-BOLTED TO ATG RISER (2 LOC) <br /> HOUSING 1"CLR FROM TANK HOUSING 1" CLR FROM TANK PIPE CLAMPS, SENSOR BRACKETS <br /> 0505 AND U-BOLTS BY GC <br /> 3 3 Z ° <br /> z <br /> w <br /> w <br /> 58 58 0 z co <br /> 1655 N e <br /> Z n <br /> W � <br /> 11 10 w � <br /> STRIKE PLATES STRIKE PLATES 'uZ <br /> BY TANK MFR BY TANK MFR <.E <br /> Wa w <br /> zo <br /> D ° o� <br /> z �o <br /> W J� <br /> O J J <br /> =V <br /> % U04 <br /> W N Z <br /> I.L w <N <br /> SECTION SECTION W <br /> W <br /> �~ <br /> U <br /> ROTATE VIEW AS REQUIRED FOR FIELD CONDITION NOTE: ROTATE VIEW AS REQUIRED FOR FIELD CONDITION NOTE: a <br /> VACUUM KIT(NOT SHOWN) VACUUM KIT(NOT SHOWN) <br /> ELECTRICAL PENETRATIONS INTO SUMP ARE SHOWN FOR TO BE MOUNTED TO ATG RISER. ELECTRICAL PENETRATIONS INTO SUMP ARE SHOWN FOR TO BE MOUNTED TO ATG RISER. <br /> REF SHEET G12.2 <br /> REFERENCE ONLY-COORDINATE LOCATIONS WITH REF SHEET G12.2 REFERENCE ONLY-COORDINATE LOCATIONS WITH N I p� O = <br /> 03 SHEET G9 AND FIELD CONDITIONS FOR VACUUM ZONES AND DETAILS. TYP 03 FOR VACUUM ZONES AND DETAILS. UJ p J <br /> SHEET G9 AND FIELD CONDITIONS N <br /> 02 TYP 02 Q O Z <br /> Z N <br /> 11 TYP 11 U) <br /> 06 MINIMUM 4'-0"STRAIGHT RUN OF TYP 06 MINIMUM 4'-0" STRAIGHT RUN OF Q m -0 <br /> 03 PIPING PRIOR TO FIRST CHANGE 03 PIPING PRIOR TO FIRST CHANGE <br /> OF DIRECTION FITTING TYP OF DIRECTION FITTING U <br /> 160 003 2" FRP X 33" LONG MIN TYP 16 ° ° 03 2" FRP X 33" LONG MIN O co <br /> (BEYOND) FOR SUMP SENSOR ° ° (BEYOND) FOR SUMP SENSOR <br /> HOUSING 1"CLR FROM TANK GO ° ° HOUSING 1"CLR FROM TANK U <br /> 11 05 10 05 0 = ui <br /> FUEL PLUMBING TREE 3 FUEL PIPING TREE 3 � 73 73 o M M o M �' 3F L 2 <br /> �� o >"wocc3 voi <br /> BELOW DISCHARGE o o BELOW DISCHARGE o o ~ °v `� `o ` m N ` `n °o <br /> ( ) o SUMP SENSOR BRACKET ( ) o SUMP SENSOR BRACKET .° ° x-E ° <br /> REF 5-G4.1 REF 5-G4.1 0 0 c m o p W� a u ° <br /> E o U-BOLTED TO ATG RISER (2 LOC) o U-BOLTED TO ATG RISER (2 LOC) �' Q� o ° o o ° o ° <br /> CONDUIT AND LBY'S TO 6 0 o PIPE CLAMPS, SENSOR BRACKETS CONDUIT AND LBY'S TO 6 0 o PIPE CLAMPS, SENSOR BRACKETS `� U r c o c>,-2.E <br /> STP POWER CONNECTION o AND U-BOLTS BY GC STP POWER CONNECTION o AND U-BOLTS BY GC <br /> N EXPLOSION PROOF 2 EXPLOSION PROOFa---___ <br /> m c - <br /> -0 m <br /> 2 EXPLOSION PROOF J-BOX o o U)•- 0 <br /> cli o J-BOX(FOR STP POWER) J-BOX(FOR STP POWER) °° ° o c �Q.o In-°a a o 0 o <br /> 2 EP J-BOX TYP SENSORS U <br /> N 7 1 S12 ( ) 7 1 512 °° ° (FOR SENSORS) � o 0 Q- °'Q� a°i-0 En <br /> En <br /> 0 o U N >,U N �� 1"5 <br /> CONDUIT FROM ELEC 6 ° o o ° S12 1 7 CONDUIT FROM ELEC ROOM 6 ° o o ° S12 1 7 .E 0-m /off��p E <br /> V L L <br /> Cj ROOM FOR STP POWER 7 CONDUIT FROM ANNULAR SPACE FOR STP POWER 7 CONDUIT FROM ANNULAR SPACE p o o o <br /> Q <br /> o MANHOLE FOR SENSORS MANHOLE FOR SENSORS <br /> �OFE,' <br /> ° ° <br /> <01 <br /> o XERXES 42" EIGHT SIDED DW U U - 35558 <br /> SUMP-SUPPLIED W/TANK(TYP) Q XERXES 42" EIGHT SIDED DW Q FL <br /> o SUMP-SUPPLIED W/TANK(TYP) N <br /> cn REF SECTION PLAN REF SECTION PLAN SOF CA4�FC <br /> w ¢ 03/26/20 <br /> SHEET: <br /> zLij D ESE STP SUMP DETAILS REGULAR AND PREMIUM STP SUMP DETAILS- G4 . 0 <br /> M <br /> cn ¢ <br /> °° Z 2 <br /> Q <br /> FUELING - USA CA <br />