My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
2300 - Underground Storage Tank Program
>
PR0545645
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:44:03 AM
Creation date
8/3/2020 12:07:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0545645
PE
2351
FACILITY_ID
FA0025876
FACILITY_NAME
7 ELEVEN INC #38877
STREET_NUMBER
1515
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15904026
CURRENT_STATUS
01
SITE_LOCATION
1515 E MAIN ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 GENERAL NOTES <br /> VAPOR FILL <br /> FOAM FORM FILL <br /> 1 ALL VACUUM TUBING MUST BE VEEDER ROOT <br /> 3 MAT LAY-UP APPROVED VACUUM TUBING. <br /> FOAM FORM INSIDE&OUTSIDE H H H <br /> 2 AN EXTERNAL SIPHON CHECK VALVE (VEEDER o Z Z Z <br /> ROOT#3188-241-5) MUST BE USED WHEN MAKING LU LU LU <br /> 99 A VACUUM SOURCE SENSORS AND THE SIPHON cn 2 2 2 <br /> VENT PORT CARTRIDGE FOR ALL TURBINES. Q <br /> LAY-UP OVER FOR 3 ALL PENETRATIONS THROUGH TANKS SUMPS, >_ <br /> ANNULAR SPACE 6"WIDE M M M TEST PORT � �UDC SUMPS AND VENT SUMPS TO BE MADE BY A � <br /> LAY-UP OVER OUTER WALL 360 DEGREE TEST PORT QUALIFIED CONTRACTOR. U U U <br /> FORM 6"WIDE o 0 0 <br /> MMM 360 DEGREE C14 C14 <br /> COLLAR INNER WALL TO VAPOR mm ti 't 't <br /> 4 ALL CONTAINMENT SUMPS TO BE INSTALLED PER N N <br /> INTERSTITIAL SENSOR CONDUIT THE MANUFACTURERS INSTALLATION � o o CN <br /> DSL VENT &DISP SUMPS INSTRUCTIONS. c� CO CO <br /> UPPER SUMP WALL PIPING ®V SENSOR CONDUIT ° 100 . <br /> 0 0 0 <br /> UPPER SUMP WALL 3 MAT LAY-UP ° ° ° <br /> VACUUM PIPING �� 5 ALL CONDUIT PENETRATIONS AND J-BOXES TO <br /> INSIDE&OUTSIDEBE INSTALLED ABOVE FUEL LINE PENETRATIONS. =ADHESIVE VACUUM PIPING ° <br /> 3 MAT LAY-U P <br /> INSIDE &OUTSIDE J00 ®® NOTE: 6 CONTRACTOR SHALL POSITION LIQUID ONLY Proto 11-05-18 <br /> SUMP SENSORS AT SUMP LOW POINT ON SIDE <br /> REF SHEET G12.2 FOR ADDITIONAL CLOSEST TO PRODUCT PIPING. <br /> NOTE: VACUUM ZONES INFORMATION <br /> REF SHEET G12.2 FOR ADDITIONAL AND DETAILS. <br /> VACUUM ZONES INFORMATION <br /> LAY-UP OVER FORM AND DETAILS. BRASS BUSHING AND 35 LIQUID ONLY SENSOR ## KEY NOTES <br /> 10"WIDE M M M WITH 1-1/2"X 1/4" 3 M <br /> LIQUID ONLY SENSOR 1/4" BRASS BARB <br /> 360 DEGREE BRASS BUSHING AND TEST PORT Lo <br /> 1/4" BRASS BARB FITTING BY GC <br /> TEST PORT 1 ELECTRICAL CONDUITS TO ENTER SUMP 2" MIN r- <br /> LOWER SUMP WALL LOWER SUMP WALL LOWER SUMP WALL FITTING BY GC ❑ CONDUIT(S) � <br /> ABOVE HIGHEST PRODUCT PENETRATION. Q <br /> SUMP SECTION (FOR 28 4 VACUUM ONLY 4 ❑2 LOCATE ELECTRICAL JUNCTION BOX IN UPWARD ' LurLuuj , <br /> JFOR COLOR SCHEME OF FOR COLOR SCHEME OF POSITION AT HIGHEST LOCATION IN SUMP RISER USPILL CONTAINER COVERS VACUUM ONLY 27 SPILL CONTAINER COVERS 26 OR 2� FOR EASY ACCESS FROM ABOVE. z ZLLI LAY-UP SAMPLES SHOWN ARE FOR REFERENCE ONLY. REFER TO MANUFACTURER'S REF 5-G6.1 REF 5-G6.1 INSTALLATION INSTRUCTIONS FOR SPECIFIC LAY-UP MATERIALS AND METHODS. 2427SUMP SENSOR TO REST AT LOWEST POINT OF SUMP ^ of LJJ24 ENCLOSURE ON PRODUCT PIPING SIDE OF SUMP. z —TANK CONTRACTOR TO SUPPLY UNISTRUTBRACKETS, PIPE CLAMPS AND 2" FRP SLEEVE FOR \ Qg CONCRETE TANK SLAB 19 2-POINT MOUNTING OF THE SLEEVE. / o �TANK SUMP LAYUP DETA LS CONCRETE TANK SLAB Lu OfU) <br /> 6 a 4 68 (INTERNAL) a 4 NTS 26 68 INTERNAL) ® SET MANHOLE COVERS 1"ABOVE THE FINISH GRADEJAND SLOPE CONCRETE AWAY FROM MANWAY LL.I � Z <br /> 25 COVERS AT 2% GRADE. I m Q <br /> a 4 c 4 a - <br /> N 58 a N a ~ ~ <br /> ❑5 POSITION BALL VALVE FOR UNOBSTRUCTED USE OF U <br /> SHUT-OFF HANDLE. Q <br /> a4 6 0 4 = <br /> © TRIM MH SKIRT TO MAINTAIN 2"TO 4" CLEARANCE. o <br /> 6 C) <br /> 7 0 o SECURE FOAM PIPE INSULATION TO BOTTOM OF MH N <br /> C 2 EXPLOSION PROOF 7 0 2 EXPLOSION PROOF SKIRT. ADD INSULATION AS REQUIRED TO PREVENT cM <br /> 29 o J-BOX AND CABLE GLAND 25 J-BOX AND CABLE GLAND CONCRETE FROM BEING POURED DIRECTLY ON <br /> AS REQ'D FOR SENSOR AS REQ'D FOR SENSOR SEALED MH. <br /> 4" SCHED 40 BLACK IRON TEST FITTINGTRIM AS <br /> 29 <br /> PIPE RISER BY GC •® 4" SCHED 40 BLACK IRON o 0 Elm• TEST FITTING 7 XERXES 42" DW EIGHT SIDED SUMP- <br /> ELEC �� REQUIRED. <br /> SEAL-OFF s <br /> PIPE RISER BY GC �. ELEC SEAL-OFF <br /> XERXES 42" DW EIGHT SIDED ' 10 CONDUIT FROM ANNULAR XERXES 42" DW EIGHT SIDED o ADJUST BLACK IRON PIPE NIPPLE LENGTHS TO <br /> SUMP SPACE MH FOR SENSOR SUMP 10 CONDUIT FROM ANNULAR ALLOW NO MORE THAN 7" FROM TOP OF COVER TO <br /> 2"SCHED 40 BLACK IRON mm 12 1 10 ®® SPACE MH FOR SENSOR TOP OF SWIVEL ADAPTERS. <br /> PIPE AND FITTINGS FOR 3"SCHED 40 BLACK IRON PIPE <br /> DIESEL BY GC S1 1 10 E5] OVERFILL PREVENTION VALVE INSTALLED PER MFR'S <br /> 4"SCHED 40 BLACK IRON AND FITTINGS BY GC SPECIFICATIONS. SET OVERFILL DEVICE FOR <br /> ° PIPE RISER BY GC 4" SCHED 40 BLACK IRON RESTRICTION OF FLOW AT OR BELOW 90%TANK <br /> 31 PIPE RISER BY GC CAPACITY AND POSITIVE SHUT-OFF AT 95%TANK <br /> SUMP SENSOR BRACKET CAPACITY TO MEET NFPA 30 REQUIREMENTS. W <br /> 44 U-BOLTED TO PIPE RISER(2 LOC) SUMP SENSOR BRACKET <br /> PIPE CLAMPS, SENSOR BRACKETS U-BOLTED TO PIPE RISER(2 LOC) 10 USE ONLY ROB ROY CONDUIT TYPES <br /> 5 AND U-BOLTS BY GC PIPE CLAMPS, SENSOR BRACKETS "PERMA-COAT", "PLASTI-BOND" OR"KORKAP" <br /> AND U-BOLTS BY GC ELECTRICAL CONDUITS AT FIBERGLASS TANK <br /> 2"SCHED 40 30 03 2" FRP X 33" LONG 03 2" FRP X 33" LONG SUMPS OR WHERE BRAVO F-17-RR OR F-10-RR Z <br /> c� <br /> GALVANIZED PIPE (MIN) FOR SUMP SENSOR (MIN) FOR SUMP SENSOR ENTRY FITTINGS ARE CALLED OUT. ? <br /> ui <br /> FITTINGS FOR HOUSING 1" CLR FROM TANK HOUSING 1" CLR FROM TANK 0 <br /> w <br /> REGULAR AND05 3 05 3 Z N E <br /> PREMIUM BY GC 2" SCHED 40 w <br /> BLACK IRON w X <br /> PIPE FITTINGS 57 9 57 9 N <br /> FOR DIESEL z z Q E <br /> tri <r� w a <br /> d 12"x12"STRIKE PLATE W a w <br /> BY GC 12"x12"STRIKE PLATE <br /> Z o 3 <br /> BY TANK MFR BY TANK MFR oz a o <br /> O J J W <br /> J <br /> M <br /> =V <br /> � � U o� <br /> W Z <br /> w c N <br /> J <br /> U o <br /> SINGLE SECTION <br /> U <br /> PRODUCT OUTPUT <br /> ROTATE VIEW AS REQUIRED FOR FIELD CONDITION NOTE: SECTION Q <br /> VACUUM KIT(NOT SHOWN) ROTATE VIEW AS REQUIRED FOR FIELD CONDITION NOTE: <br /> ELECTRICAL PENETRATIONS INTO SUMP ARE SHOWN FOR TO BE MOUNTED TO ATG RISER. VACUUM KIT(NOT SHOWN) <br /> E U E P P G TREE DETA S <br /> REFERENCE 2 NCE ONLY-COORDINATE LOCATIONS WITH REF SHEET G12. TO BE MOUNTED TO ATG RISER. N 0 0 _ <br /> FOR VACUUM ZONES AND DETAILS. ELECTRICAL PENETRATIONS INTO SUMP ARE SHOWN FOR N W <br /> � p J <br /> 5 SHEET G9.0 AND FIELD CONDITIONS REFERENCE ONLY-COORDINATE LOCATIONS WITH REF SHEET G12.2 m Z <br /> SHEET G9.0 AND FIELD CONDITIONS FOR VACUUM ZONES AND DETAILS. Q 0 N <br /> 02 VAPOR (n <br /> 03 01 Q m <br /> 02 �•oiG"90G 12 m N <br /> 11 <br /> ° ° <br /> 06 ° ° ° 18 U) 0 0 U <br /> PIPE RISER °° <br /> SUMP SENSOR BRACKET FITTING FOR VACUUM ° 2"SCHED 40 GALVANIZED �°-� 3 3 az <br /> U-BOLTED TO PIPE RISER MONITORING, REF 2-G12.2 SUMP SENSOR BRACKET PIPE AND FITTINGS FOR m o a �°, n o <br /> (2 LOC) PIPE CLAMPS, U-BOLTED TO PIPE RISER 2 LOC REGULAR AND PREMIUM BY GC o o E c <br /> SENSOR BRACKETS 2"SCHED 40 BLACK IRON ( ) SUMP SENSOR BRACKET -0 o o- c m 0 p voi a cm <br /> PIPE CLAMPS, SENSOR BRACKETS L o c c O a> c U) <br /> AND U-BOLTS BY GC PIPE AND FITTINGS FOR DIESEL 4" SCHED 40 BLACK IRON PIPE U-BOLTED TO PIPE RISER(2 LOC) a� m U - o a� >,� o <br /> BY GC RISER BY GC PIPE CLAMPS, SENSOR BRACKET: Q c ° F-� 3 c <br /> AND U-BOLTS BY GC L - U•-� ��� o c� c•-.� <br /> Fo <br /> 03 <br /> AND U-BOLTS BY GC ;v o x-u o"516 m.c <br /> 2" FRP X 33" LONG <br /> 4" SCHED 40 BLACK IRON 31 <br /> o (MIN) FOR SUMP SENSOR PIPE RISER BY GC 4" SCHED 40 BLACK IRON a� voi c ami o E <br /> c"iHOUSING 1" CLR FROM TANK Gp a) c= c Q c 0= o <br /> �.._ <br /> N PIPE RISER BY GC E•o L o c <br /> cc� 44 4"SCHED 40 BLACK IRON �, a a U - <br /> M GO 2 EXPLOSION PROOF J-BOX AND I SCHED 40 BLACK IRON E o.Q m o L � <br /> a 05 PIPE AND FITTINGS BY GC o c L °� o - <br /> PIPE RISER BY GC U r'R c:° c c azo n <br /> CABLE GLAND AS REQUIRED FITTING FOR VACUUM c 0'L <br /> 0 16 MONITORING, REF 1-G12.2 ° 2 EXPLOSION PROOF J-BOX AND - <br /> z 3 12 1 10 06 ° CABLE GLAND AS REQUIRED <br /> ° <br /> 03 ° ° 10 CONDUIT FROM ANNULAR <br /> 06 SPACE MH FOR SENSOR 11 ° ° 10 CONDUIT FROM ANNULAR T �% <br /> 03 2" FRP X 33" LONG GJJ� ° ° SPACE MH FOR SENSOR R' <br /> SUMP SENSOR A D 02 35558 <br /> N) FOR SUMP SENSOR <br /> 11 03 2" FRP X 33" LONG <br /> SENSOR BRACKET DETA 02 VENT HOUSING 01 HOUSING 9�FCHAWC'P <br /> N) FOR SUMP SENSOR <br /> (171 <br /> VENT F OF Cpl\FO <br /> N3/4"=l'-O" 03 PLAN 05 3 <br /> Y02 <br /> W 03 PLAN 06 03/26/20 <br /> CD <br /> zW <br /> z DIESEL E VENT DETAILS RU 8c PULE VENT /VAPOR SUMP DETAILS <br /> mUSED <br /> 2 3/4"=1'-0" 1 3/4"=1'-0" G4 . 1 <br /> '= c_D <br /> Lu <br /> 'cil 9 <br /> N3/ r <br /> FUELING - USfCA <br />
The URL can be used to link to this page
Your browser does not support the video tag.