Laserfiche WebLink
CLEARWATER <br /> G R o U P, I N C <br /> 1 <br /> 1.0 INTRODUCTION <br /> This report presents the results of quarterly groundwater monitoring performed by <br /> Clearwater Group, Inc (Clearwater) on November 30, 1995 at 1002 North Yosemite <br /> ' Street in Stockton, California (Figure 1) The tasks performed during this phase of <br /> work included groundwater gauging, well purging and groundwater sample <br /> collection <br /> ' 2.0 BACKGROUND <br /> No aboveground structures are present at the subject location, it is a vacant lot <br /> surrounded by a chain-link fence Records indicate that the subject site was used as a <br /> gasoline service station from 1961 to 1978, and that the underground fuel storage <br /> tanks were rovein . n environmental assessment conducted in 1990 b <br /> I ' eemd 1980Atl dd Y <br /> Evax Technologies, Inc consisted of a limited soil gas survey The purpose of this <br /> ' investigation was to identify any potential subsurface contamination in the vicinity <br /> of the three former underground storage tanks The soil gas survey indicated the <br /> possible presence of petroleum hydrocarbons in the soil <br /> Following this initial discovery, GeoAudit was retained to conduct a more <br /> comprehensive subsurface investigation The investigation consisted of drilling six <br /> ' soil borings to depths from between 29 5 and 36.5 feet below ground surface (bgs), <br /> and collecting soil samples at five foot intervals Laboratory analysis of soil samples <br /> collected by GeoAudit indicated the presence of relatively low levels of ethylbenzene <br /> ' in the soil around the western edge of the property Subsequently, San Joaquin <br /> County Public Health Services Environmental Health Division (PHS/EHD) directed <br /> the property owner to install rnorutormg wells and to begin quarterly sampling <br /> ' In accordance with PHS/EHD directives, GeoAudit completed installation and <br /> sampling of three groundwater morutormg wells (MW-1 through MW-3) in October <br /> ' 1993 The highest concentrations of volatiles were found in groundwater samples <br /> collected from MW-2, located near the former tank area A detailed presentation of <br /> the initial site assessment can be found in GeoAudit's November 1993 "Monitoring <br /> Well Installation and Quarterly Report". <br /> ' To further evaluate the extent of hydrocarbon distribution in groundwater, <br /> Clearwater installed monitoring wells MW-4 and MW-5 on August 31, 1994 MW-5 <br /> was installed approximately 50 feet downgradient of MW-2 At the request of the <br /> ' PHS/EHD, MW-4 was installed as an additional data point to evaluate possible <br /> . fluctuations in the groundwater flow direction Water level and surveying data <br /> compiled over the past year indicates a fairly consistent northwestern groundwater <br /> I ' flow direction <br /> l <br /> D-101 4Q95 1 January 25, 1996 <br /> 1 <br />