Laserfiche WebLink
1 <br /> Management Provisions <br /> Treated wastewater from the WWTP will be discharged at a subsurface dispersal system located <br /> on the golf course. The dispersal pipe will be covered with a minimum of one foot of native soil. <br /> Treated wastewater applied to the subsurface will migrate downward through a trench filled with <br /> 3/8"drain rock and absorb into the native soil through the trench walls. <br /> Because treated wastewater discharged at the subsurface dispersal system will be separated from <br /> + the public by at least one foot of native soil,the public will not come in contact with the applied <br /> wastewater. <br /> In addition to the management provisions listed above, a 100-foot setback between surface water <br /> features at the golf course and the subsurface dispersal areas will be maintained. <br /> t <br /> An area at the RV Park golf course has been set aside to be used for the replacement of the <br /> subsurface dispersal areas if necessary. The location of the reserve area is shown in Figure 2. <br /> Building or other modifications that would impede the construction of a subsurface dispersal <br /> area will be prohibited in the reserve area. <br /> i <br /> RESPONSIBLE PERSON <br /> This information is provided in Form 200, as presented in Appendix A. <br /> MONITORING AND REPORTING PROGRAM <br /> To monitor performance of the WWTP and subsurface dispersal areas,it is proposed that the <br /> following monitoring and reporting schedule be implemented. <br /> Influent Monitoring <br /> Samples will be collected from the influent of the WWTP. Samples will be collected at the same <br /> frequency and at approximately the same time as effluent samples and will be representative of <br /> the influent at the headworks prior to treatment. Influent monitoring will include, at a minimum, <br /> the elements shown in Table 9. <br /> Effluent Monitoring <br /> F <br /> Samples will be collected from the effluent of the WWTP. Effluent samples shall be collected <br /> downstream from the last connection prior to discharge to the buried storage tanks. Effluent <br /> monitoring will include, at a minimum,the elements shown in Table 10. <br /> Subsurface Dispersal Area Monitoring <br /> Monitoring of the treated wastewater applied to the subsurface dispersal areas will be performed. <br /> Recycled water will be monitored to ascertain loading rates at the subsurface dispersal areas to <br /> i ensure the protection of surface and groundwater. Evidence of erosion, field or soil saturation., <br /> French Camp—Report of Waste Discharge 8 SAB027102 <br /> July 2008 n:lsab027102\ducuments\rwd\frenchcamprwdjuly rev final.doc <br />