My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SIKORSKY
>
2050
>
2200 - Hazardous Waste Program
>
PR0540720
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2020 2:16:20 PM
Creation date
8/5/2020 2:06:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0540720
PE
2220
FACILITY_ID
FA0023280
FACILITY_NAME
JC AIR ACADEMY INC
STREET_NUMBER
2050
Direction
E
STREET_NAME
SIKORSKY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
2050 E SIKORSKY ST
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />8/23/2019 <br />Small Quantity Hazardous Waste Generator Inspection Report <br />Date: <br />July 15, 2019 <br /> Facility Address: <br /> 2050 E SIKORSKY ST, STOCKTON <br /> Facility Name: <br /> JC AIR ACADEMY INC <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br />equipment. <br />Approximately 2-3 gallons of used oil was observed in the secondary containment in the storage hanger. All facility <br />communications or alarm systems, fire protection equipment, spill control equipment, and decontamination <br />equipment, where required, shall be tested and maintained as necessary to assure its proper operation in time of <br />emergency. Immediately empty the secondary containment and begin this practice. <br />This is a Class II violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br />waste. <br />In the main shop, nine 5 gallon plastic buckets containing used oil were missing lids. <br />All hazardous waste containers shall be closed at all times except when adding or removing waste. Immediately <br />close these containers and ensure all hazardous waste containers are closed when not adding or removing waste. <br />This is a Class II violation. <br /> 505 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks. <br />The used oil tank (1/8 full) in the storage hanger did not have a hazardous waste label. All hazardous waste tanks <br />shall be marked with the words “Hazardous Waste” and the accumulation start date. Immediately ensure that all <br />hazardous waste tanks are marked with the required information. <br />This is a Class II violation. <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days. <br />The used oil tank in the storage hanger did not have an accumulation start date. <br />Facilities who generate less than 1000 kg of hazardous waste per month and do not exceed 6000 kg of waste <br />stored on site at any time may store waste on site up to 180 days. Since it cannot be determined how long the <br />hazardous waste in the used oil tank has been on site, immediately contact a licensed hazardous waste hauler to <br />dispose of this waste under manifest. Submit a copy of the manifest to the EHD within 30 days. <br />This is a Class II violation. <br />Page 7 of 9 <br />FA0023280 PR0540720 SC001 07/15/2019 <br />EHD 22-01 Rev. 09/27/2018 Small Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.