Laserfiche WebLink
ATTACHMENT A <br /> SAMPLING AND ANALYSIS PROCEDURES <br /> The sampling procedures for water quality monitoring programs are contained in this attachment <br /> The procedures provided for consistent and reproducible sampling methods, proper apphcatnon of <br /> analytical methods, and accurate and precise analytical results Finally, these procedures provided <br /> guidelines so that the overall objectives of the monitoring program were achieved <br /> The following documents have been used as guidelines for developing these procedures <br /> • Procedures Manual for Groundwater Monitoring at Solid Waste Disposal Facilities, <br /> Environmental Protection Agency (EPA)-530/SW-611, August 1977 <br /> • Resource Conservation and Recovery Act (RCRA) Groundwater Monitoring Technical <br /> Enforcement Guidance Document, Office of Solid Waste and Emergency Response <br /> (OSWER) 9950 1, September 1986 <br /> • Test Methods for Evaluating Solid Waste Physical/Chemical Methods, EPA SW-846, <br /> 3rd edition,November 1986 <br /> • Methods for Organic Chemical Analysis of Municipal and Industrial Waste Water, <br /> EPA-600/4-82-057, July 1982 <br /> • Methods for Organic Chemical Analysts of Water and Wastes, EPA-600/4-79-020, revised <br /> March 1983 <br /> • Lealang Underground Fuel Tank (LUFT) Field Manual, California State Water Resources <br /> Control Board, revised October 1989 <br /> Sample Collection <br /> Sample collection procedures include equipment cleaning, water level and total well depth <br /> measurements,and well purging and sampling <br /> SAC�N\ADIMBodERS&APARCo DOC <br />