SU0013544
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HANSEN
>
26603
>
2600 - Land Use Program
>
PA-2000083
>
SU0013544
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2022 4:40:33 PM
Creation date
8/7/2020 11:07:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013544
PE
2631
FACILITY_NAME
PA-2000083
STREET_NUMBER
26603
Direction
S
STREET_NAME
HANSEN
STREET_TYPE
RD
City
TRACY
Zip
95377-
APN
20911004
ENTERED_DATE
7/27/2020 12:00:00 AM
SITE_LOCATION
26603 S HANSEN RD
RECEIVED_DATE
3/22/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the gate controller. Electric gate operators shall be listed in accordance with UL 325 and ASTM <br /> F2200. t<nox switches shall be provided on both sides of the gates unless an exit loop is provided at <br /> automatic gates. The automatic gates shall have a battery back-up or a manual mechanical <br /> disconnect readily accessible to emergency personnel in case of power failure. <br /> G. New and existing building shall be provided with approved address identification in accordance <br /> with CFC §505. <br /> 7. Prior to Foal inspection, emergency radio responder coverage shall be tested to confirm coverage <br /> areas. It is beneficial For the applicant to conduct testing at foundation as retrofitting for the conduit <br /> is costly. If coverage is inadequate,a separate permit for emergency radio responder coverage shall <br /> be submitted to SSJCFA for review and approval prior to installation. <br /> a. Additional improvements may warrant additional testing to be performed. Testing shall be <br /> the determination of the fire code ofFcial. <br /> 8. Additional comments may occur upon submittal of construction documents. <br /> When addressing tfie comments of revised plans,submit a written response to each comment. Using <br /> complete and clear responses will expedite tfie re-check and approval of the project. <br /> Indicate which details, specifications, and/or calculations show the requested correction by clouding all <br /> revisions and show revised delta designation for all changes. Identify the revisions in the revision box with <br /> a corcesponding date and type of correction. <br /> Failure to cloud any changes or provid¢a detail¢d respons¢upon resubmittal will result in rej¢etiov <br /> of the saabmitted plans. <br /> If any changes have been made to the plan documents unrelated to those items identified in the comment <br /> lists,please list the changes on a separate sheet and include in your submittal documentation. <br /> An application for permit for any proposed work shall be deemed to have been abandoned 180-days atter <br /> the date of filing(submittal date). The abandoned permit will be expired and new fees must be paid. The <br /> applicant may request a 90-day extension by submitting a letter to the Pire Marshal at <br /> fire.planchcck a s'clire-ora,demonstrating justifiable cause,prior to the expiration date. <br /> Resubmit plans, supporting documents and response letters to the fire.plancheck[7sicF re.oru. Do not <br /> ¢mail PDF documents directly to plan r¢view¢r_ <br /> Please note,additional comments may occur upon resubmittal. <br /> Feel free to contact our ofFces, should you have any questions. <br /> Thank you, <br /> 2 <br />