159'-8" <br />40'-8"80'-0"39'-0" <br />9'-0"19'-10"11'-2"8'-10"19'-10"11'-4"183'-11"210'-7"25'-4"40'-0"40'-0"40'-0"38'-7"26'-8"8'-4"18'-4"9'-3"1PROPOSED ROOF PLANSCALE1/8" = 1' - 0"CSCHEDULE OF KEYED NOTESSCALEN/ABGENERAL NOTESSCALEN/AALEGENDSCALEN/A9000 (E) ROOFING SYSTEM TO REMAIN - PROTECT IN PLACE.9002 (E) FRONT CANOPY STRUCTURE TO REMAIN - PROTECT IN PLACE.9003 (E) HVAC EQUIPMENT TO REMAIN (RE: MECHANICAL DWGS FOR ADDITIONALINFORMATION)9004 (N) EXHAUST FAN. (RE: MECHANICAL DRAWINGS).9001 PATCH & REPAIR (E) ROOFING SYSTEM WHERE ADJACENT TO NEW CONSTRUCTION.(USE LANDLORD'S ROOFER)9005 (E) ROOF DRAIN TO REMAIN, TYP. - PROTECT IN PLACE.9006(E) AIR COOLER CONDENSER TO REMAIN - PROTECT IN PLACE(RE: MECHANICAL & REFRIGERATION DRAWINGS).(E) ROOF ACCESS HATCH TO REMAIN - PROTECT IN PLACE9007(E) WALKWAY PADS TO REMAIN - PROTECT IN PLACE90081.VERIFY SIZES AND LOCATIONS OF ALL ROOF OPENINGS, PLATFORMS, ETC. WITHRESPECTIVE CONTRACTORS.2.WHERE VENT PIPES PENETRATE ROOF SHEATHING REFER TO DETAIL 8/A-9.0 . REFER TOPLUMBING DRAWINGS FOR PLUMBING VENTS AND PIPES THROUGH ROOF WHICH MAY NOTBE SHOWN ON THIS ROOF PLAN. PROVIDE FLASHING AND COUNTER FLASHING AT (N)MECHANICAL EQUIPMENT CURBS AND VENTS. REFER TO MECHANICAL DRAWINGS &REFRIGERATION PLANS FOR OPENINGS AND VENTS THROUGH ROOF WHICH MAY NOT BESHOWN ON THIS ROOF PLAN.3.ALL EXPOSED ROOF MOUNTED EQUIPMENT (I.E. HOODS, VENTS, ETC.) SHALL RECEIVETWO COATS OF PAINT. COLOR TO BE SELECTED BY ARCHITECT. CONTRACTOR SHALLVERIFY LOCATION AND SIZE OF ALL ROOF OPENINGS AND EQUIPMENT PLATFORMSREQUIRED. DUCT ALL ROOF EXHAUST VENTS/FANS TO THEIR RESPECTIVE OPENINGS INROOM BELOW.4.WHERE APPLICABLE, TENANT MUST PROVIDE DRAFT STOPS AT ATTICS, MANSARDS,OVERHANGS AND FALSE FRONTS SET OUT FROM WALLS AND SIMILAR CONCEALEDSPACES OF BUILDING WHERE THE CONCEALED SPACE EXCEEDS 3000 S.F. AND THEGREATEST HORIZONTAL DIMENSION EXCEEDS 60 FEET TO DIVIDE ATTICS TO A MAXIMUM3,000 S.F. AND A MAXIMUM HORIZONTAL DIMENSION OF 60 FEET. IF FULLY SPRINKLERED AMAXIMUM OF 9,000 S.F. AND A MAXIMUM HORIZONTAL DIMENSION OF 100 FEET.5.ALL (N) A/C - REFRIGERATION UNITS SHALL BE PLACED ON FACTORY ROOF CURBS ANDLOCATED IN AREA DESIGNATED FOR MECHANICAL EQUIPMENT.6.ALL OPENINGS AT ROOF LARGER THAN 9 INCH X 9 INCH SHALL BE PROTECTED WITHBURGLAR BARS PROVIDED AND INSTALL BY GENERAL CONTRACTOR. THE SPACING OFBARS SHALL NOT EXCEED 5 INCHES. REFER TO DETAIL 13/A4.1.(E) ROOF ACCESS HATCH(N) GRAVITY VENT(N) EXHAUST FANS7. CERTIFIED ROOFING CONTRACTOR DOING REMEDIAL PATCHING SHALL PROVIDE A CERTIFICATION STATING THAT THE ROOF HAS BEEN APPLIED PER MANUFACTURER'S RECOMMENDATIONS. USING CLASS 'A' FIRE RATED MATERIALS. ALL WORK ON THE ROOF SHALL COMPLY WITH 'NO DOLLAR LIMIT' WARRANTY.8. FOR (E) ROOF FRAMING REFER TO STRUCTURAL DRAWINGS.9. ALL ROOF MATERIALS AND ACCESSORIES ARE TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.10. SEE MECHANICAL, ELECTRICAL & REFRIGERATION PLANS FOR ADDITIONAL ROOFPENETRATIONS NOT SHOWN HERE.11. RESTORE EXISTING ROOFING STRUCTURE AND SYSTEM TO NEW CONDITION WHEREDAMAGED BY THE CONSTRUCTION OF NEW MECHANICAL/REFRIGERATION WORK DONE.12. IF NEW EQUIPMENT IS BEING ADDED TO THE ROOF, FIRST OPTION TO BE SET ON RUNNERSAND SECOND OPTION TO BUILD PLATFORM.(E) CRICKET SLOPEDIRECTION,(E) ATTIC TOWER VENT INVERTICAL WALL(E) ROOF DRAIN & OVERFLOWSCUPPERINDICATES (E) ACCESS DOOR9000900190029003TYP.9003TYP.90049005900590079008TYP.9008TYP.90069006Filename:Sheet Title:Date:Scale:Project No.: Drawn By:Reviewed By:No.MCG ARCHITECTS 2018 ALL RIGHTS RESERVEDCSheet #:09-18-18Description18.452DateRevisions:Client:A Project for:Seal:TEAM600 CITADEL DRIVE,COMMERCE, CA 90040Tel. (323) 869 7500Fax (323) 869 7856TENANT IMPROVEMENT <br />STOCKTON, CA 95207 <br />SMART & FINAL #393 <br />744 WEST HAMMER LANE <br />AS NOTED10.22.181ST SUBMITTALA9.0ROOF PLAN