My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
744
>
1600 - Food Program
>
PR0529790
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2020 3:29:09 PM
Creation date
8/11/2020 3:24:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0529790
PE
1619
FACILITY_ID
FA0019653
FACILITY_NAME
Smart Final #393
STREET_NUMBER
744
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
744 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REMARKS PLUMBINGHWCWDIR.F.S.ITEM NO.DESCRIPTIONMANUFACTURERMODELNEW EQUIPMENT SCHEDULEMEAT PREP AND COOLERNSFCERT.MA-06MA-05MA-04MA-03MA-02MA-01S.S. PREP SINKS.S. HAND SINKS.S. 3-COMP SINKROTISSERIE OVENPRODUCE PREP AND COOLERS.S. DUNNAGE RACKADVANCE TABCOADVANCE TABCOADVANCE TABCOCAPTIVE AIREJMG SPECIALTIES, INC.93-1-24-18RL7-PS-6693-3-54-18RLTE 102PA-04PA-03PA-02PA-01S.S. HAND SINKS.S. PREP SINKADVANCE TABCOADVANCE TABCOADVANCE TABCO93-1-24-18RL7-PS-6693-3-54-18RLJMG SPECIALTIES, INC.6' S.S. PREP TABLE W/ POLY BD. TOPS.S. 3-COMP SINK109243 TIER SHELVINGPA-05SEE NOTE #1PA-0624" X 48" X 18" SHELVINGJMG SPECIALTIES, INC.JM-AL-BCS-2448-3SEE NOTE #2AEQUIPMENT SCHEDULESCALEN/A11452MA-0724" X 48" X 18" SHELVINGJMG SPECIALTIES, INC.JM-AL-BCS-2448-3MA-08ISHIDA NANO SCALENOTES:1) MEAT WRAP AREA WILL BE FOR PREPARING RAWCHICKEN TO BE COOKED, COOKING CHICKEN, THENWRAPPING THE COOKED CHICKEN ONLY.2) PROVIDE SPLASH GUARDS ON BOTH SIDES OFHANDSINK IN PRODUCE AND MEAT PREP. ROOMSMA-096' WORK TABLENOTE: REFER TO REFRIGERATIONSHEETS FOR REFRIGERATIONEQUIPMENT SCHEDULE3) INTERTEK ETL AGENCY APPROVEDSA-01CHICKEN WARMERBKIMM-6SEE NOTE #3HOODCOMBI-KING5424 ND2SEE NOTE #44) REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFO.5) REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFO.6) 150,00 BTU / HR., 171 GPH AT 1 HR. - 100 DEG. F. RISE.7) LOCATED AT THE MEZZANINES.S. DUNNAGE RACKJMG SPECIALTIES, INC.10924PA-07159'-8" <br />40'-8"80'-0"39'-0" <br />9'-0"19'-10"11'-2"8'-10"19'-10"11'-4"183'-11"210'-7"25'-4"40'-0"40'-0"40'-0"38'-7"26'-8"10'-0"8'-0"6'-6"8'-0" <br />7'-0" <br />7'-7"7'-0"9'-412"7'-4"7'-11"11'-1"3'-11"4'-1"4'-0"4'-1"4'-0"4'-1"4'-0"4'-1"4'-0"4'-1"4'-0"4'-1"4'-0"14'-4"12'-0"7'-6"9'-8"9'-8"7'-6"7'-0"7'-0"7'-0"6'-7"6'-7"6'-8"15'-1"5'-0"6'-012"7'-7"5'-0"5'-0" <br />4'-912" <br />6'-0"6'-0"4'-1112" <br />7'-0"4'-9"4'-0 <br />"4'-0 <br />"9'-312"6'-0"8'-0"5'-2"5'-2"7'-0"11'-1"9'-1"6'-6"6'-6"7'-0"5'-3"4'-0"8'-4"18'-4"9'-3"FEFEFEFEFENTABLE 1017.2MAXIMUM TRAVEL DISTANCE REQUIRED 250'OCCUPANCY WITHOUT SPRINKLERS WITH SPRINKLERSTYPE M 200' 250'1.THIS BUILDING MUST BE EQUIPPED WITH AN AUTOMATIC FIRE EXTINGUISHINGSYSTEM COMPLYING WITH (NFPA-13). THE SPRINKLER SYSTEM SHALL BE APPROVEDBY FIRE PLAN REVIEW PRIOR TO INSTALLATION. (CFC 903.3.1)2.ADDRESS SHALL BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET FRONTINGTHE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND.NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH A MINIMUM STROKE WIDTHOF 0.5 INCH.3.A MINIMUM OF ONE 2A 10-B:C FIRE EXTINGUISHER SHALL BE PROVIDED FOR EVERY75 FEET OF TRAVEL DISTANCE.4.COMBUSTIBLE DEBRIS SHALL NOT BE ACCUMULATED WITHIN BUILDINGS.COMBUSTIBLE DEBRIS, RUBBISH AND WASTE MATERIAL SHALL BE REMOVED FROMBUILDINGS AT THE END OF EACH SHIFT OF WORK. (CFC 3304.2)5.MATERIALS SUSCEPTIBLE TO SPONTANEOUS IGNITION, SUCH AS OILY RAGS, SHALLBE STORED IN A LISTED DISPOSAL CONTAINER. (CFC 3304.2.4)6.OPERATIONS INVOLVING THE USE OF CUTTING AND WELDING SHALL BE DONE INACCORDANCE WITH CFC CHAPTER 26. (CFC 3304.6)7.LABELING. DOORS INTO ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKEDWITH A PLAINLY VISIBLE AND LEGIBLE SIGN STATING 'ELECTRICAL ROOM' OR SIMILARAPPROVED WORDING.8.LABELING. DOORS INTO FIRE ALARM CONTROL PANEL ROOMS SHALL BE MARKEDWITH A PLAINLY VISIBLE AND LEGIBLE SIGN STATING 'FIRE CONTROL PANEL' ORSIMILAR APPROVED WORDING.9.REAR ADDRESS NUMBERS. ALL MULTI-TENANT BUILDINGS SHALL BE PROVIDED WITHADDRESS NUMBERS AND/OR SUITE NUMBERS ON THE REAR DOORS TO EACHTENANT SPACE.10.REAR EXIT DOORS SHALL BE PROVIDED WITH SIGNAGE STATING, 'EXIT DOOR DONOT BLOCK'.11.PROVIDE A READILY VISIBLE DURABLE SIGN ABOVE THE MAIN ENTRANCE DOORSTATING 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED'.12.PROVIDE A KNOX BOX OR UPDATE KEYS.BFIRE DEPT. NOTESSCALEN/A1FIXTURE FLOOR PLANSCALE1/8" = 1' - 0"TRAVEL DISTANCE = 172'-4"TRAVEL DISTANCE = 187'-4"MA-09MA-05SA-01MA-04MA-02MA-03MA-01MA-06MA-08PA-01PA-02PA-06PA-03PA-04PA-07Filename:Sheet Title:Date:Scale:Project No.: Drawn By:Reviewed By:No.MCG ARCHITECTS 2018 ALL RIGHTS RESERVEDCSheet #:09-18-18Description18.452DateRevisions:Client:A Project for:Seal:TEAM600 CITADEL DRIVE,COMMERCE, CA 90040Tel. (323) 869 7500Fax (323) 869 7856TENANT IMPROVEMENT <br />STOCKTON, CA 95207 <br />SMART & FINAL #393 <br />744 WEST HAMMER LANE <br />AS NOTED10.22.181ST SUBMITTALA10.0FIXTURE PLAN
The URL can be used to link to this page