Laserfiche WebLink
In-N-Out Burgers NGF 255 Progate Drive Thru Service Manual <br />Publication Number: 621058475SER - 26 -© 2011, IMI Cornelius Inc. <br />BEVERAGE NOT <br />BEVERAGE NOT DISPENSING <br />Is the key switch <br />on/off <br />1. Check the key switch <br />Off <br />Is <br />there power on <br /> the line side of the <br />transformer <br />On <br />1. Check the transformer <br />connections to the E-Board in <br />the E-Box. <br />2. Check the E - Board in the E- <br />Box ensuring that power is <br />being supplied to the board. <br />No <br />Is <br />there power on the <br />load side of the <br />transformer <br />Yes <br />1. Check the transformer. <br />2. Change the transformer. <br />No <br />1.Check the wire harness from the <br />beverage valves to the terminal board. <br />2. Check the beverage dispense valve to <br />ensure that they are functioning. <br />3. Change beverage valve. <br />4. Check the water line to the valve and the <br />syrup line to the valve. <br />Yes <br />DISPENSING