1030A215-Mar2008 1130A215-Mar2008 <br /> <br />INLET GAS LINE REQUIREMENTS <br />PIPE <br />LENGTH <br />PIPE DIAMETERS (inches & (mm equivalents)) <br />Maximum Allowable Flow (Shown in ft3/hr (M3/hr)) <br />Feet <br />(Meters) <br />15 <br />(4.6) <br />62 <br />(1.7) <br />170 <br />(4.7) <br />350 <br />(9.8) <br />620 <br />(17.4) <br />960 <br />(26.9) <br />2,000 <br />(56.0) <br />3,500 <br />(98.0) <br />5,400 <br />(151.2) <br />11,200 <br />(313.6) <br />30 <br />(9.1) <br />43 <br />(1.2) <br />120 <br />(3.4) <br />245 <br />(6.9) <br />430 <br />(12.0) <br />680 <br />(19.0) <br />1,400 <br />(39.2) <br />2,450 <br />(68.6) <br />3,800 <br />(106.4) <br />7,900 <br />(221.2) <br />45 <br />(13.7) <br />35 <br />(1.0) <br />98 <br />(2.7) <br />200 <br />(5.6) <br />355 <br />(9.9) <br />530 <br />(14.8) <br />1,150 <br />(32.2) <br />2,000 <br />(56.0) <br />3,200 <br />(89.6) <br />7,900 <br />(182.0) <br />60 <br />(18.3) <br />30 <br />(0.8) <br />84 <br />(2.4) <br />175 <br />(4.9) <br />310 <br />(8.7) <br />480 <br />(13.4) <br />1,000 <br />(28.0) <br />1,760 <br />(49.3) <br />2,700 <br />(75.6) <br />5,600 <br />(156.8) <br />75 <br />(22.9) <br />27 <br />(0.8) <br />76 <br />(2.1) <br />155 <br />(4.3) <br />275 <br />(7.7) <br />430 <br />(12.0) <br />890 <br />(24.9) <br />1,560 <br />(43.7) <br />2,450 <br />(68.6) <br />5,000 <br />(140.0) <br />90 <br />(27.4) <br />25 <br />(0.7) <br />70 <br />(2.0) <br />145 <br />(4.1) <br />250 <br />(7.0) <br />395 <br />(11.1) <br />810 <br />(22.7) <br />1,430 <br />(40.0) <br />2,260 <br />(63.3) <br />4,550 <br />(127.4) <br />105 <br />(32.0) <br />23 <br />(0.6) <br />64 <br />(1.8) <br />132 <br />(3.7) <br />232 <br />(6.5) <br />370 <br />(10.4) <br />(750 <br />(21.0) <br />1,300 <br />(36.4) <br />2,100 <br />(58.8) <br />4,200 <br />(117.6) <br />120 <br />(36.6) <br />21 <br />(0.6) <br />60 <br />(1.7) <br />125 <br />(3.5) <br />215 <br />(6.0) <br />340 <br />(9.5) <br />700 <br />(19.6) <br />1,200 <br />(33.6) <br />1,950 <br />(54.6) <br />4,000 <br />(112.0) <br />150 <br />(45.7) <br />19 <br />(0.5) <br />54 <br />(1.5) <br />110 <br />(3.1) <br />195 <br />(5.5) <br />310 <br />(8.7) <br />630 <br />(17.6) <br />1,080 <br />(30.2) <br />1,750 <br />(49.0) <br />3,550 <br />(99.4) <br />180 <br />(54.9) <br />17 <br />(0.5) <br />49 <br />(1.4) <br />100 <br />(2.8) <br />175 <br />(4.9) <br />280 <br />(7.8) <br />570 <br />(16.0) <br />960 <br />(26.9) <br />1,600 <br />(44.8) <br />3,200 <br />(89.6) <br />210 <br />(64.0) <br />16 <br />(0.4) <br />44 <br />(1.2) <br />94 <br />(2.6) <br />165 <br />(4.6) <br />260 <br />(7.3) <br />530 <br />(14.8) <br />890 <br />(24.9) <br />1,450 <br />(40.6) <br />3,000 <br />(84.0) <br />240 <br />(73.2) <br />15 <br />(0.4) <br />43 <br />(1.2) <br />88 <br />(2.5) <br />155 <br />(4.3) <br />240 <br />(6.7) <br />500 <br />(14.0) <br />840 <br />(23.5) <br />1,350 <br />(37.8) <br />2,800 <br />(78.4) <br />270 <br />(82.3) <br />14 <br />(0.4) <br />40 <br />(1.1) <br />83 <br />(2.3) <br />145 <br />(4.1) <br />230 <br />(6.4) <br />470 <br />(13.2) <br />780 <br />(21.8) <br />1,300 <br />(36.4) <br />2,650 <br />(74.2) <br />300 <br />(91.4) <br />14 <br />(0.4) <br />38 <br />(1.1) <br />79 <br />(2.2) <br />138 <br />(3.9) <br />215 <br />(6.0) <br />440 <br />(12.3) <br />750 <br />(21.0) <br />1,250 <br />(35.0) <br />2,500 <br />(70.0) <br />450 <br />(137.2) <br />11 <br />(0.3) <br />31 <br />(0.9) <br />64 <br />(1.8) <br />112 <br />(3.1) <br />176 <br />(4.9) <br />360 <br />(10.1) <br />630 <br />(17.6) <br />1,000 <br />(28.0) <br />2,050 <br />(57.4) <br />600 <br />(182.9) <br />10 <br />(0.3) <br />27 <br />(0.8) <br />56 <br />(1.6) <br />97 <br />(2.7) <br />152 <br />(4.3) <br />315 <br />(8.8) <br />530 <br />(14.8) <br />860 <br />(24.1) <br />1,750 <br />(49.0) <br /> <br /> NOTE: 1) FT3/HR (M3/HR) values may vary due to heating value and specific gravity of gas supplied by local companies. <br /> 2) To determine the inlet gas line diameter for the distance between the fryer and main gas regulator, locate the FT3/HR (M3/HR) of gas required for the fryer and <br /> pipe length and read the pipe diameter on the top row. For example: a 14” PD fryer operating on NATURAL GAS requires 105 FT3/HR (3.0 M3/HR) <br /> of gas at the fryer’s inlet gas manifold. If the fryer bank is located 60 feet from the building gas regulator, a 1” (25mm) diameter gas line MUST be installed <br /> between the manifold and regulator. <br />1⁄2” <br />(13 mm) <br />3⁄4” <br />(19mm) <br />1” <br />(25mm) <br />11⁄4” <br />(32mm) <br />11⁄2” <br />(38mm) <br />2” <br />(51mm) <br />21⁄2” <br />(64mm) <br />3” <br />(76mm) <br />4” <br />(102mm) <br />I. INLET GAS LINE SIZING: <br /> The Table below is to be utilized to calculate the size (diameter) of the inlet gas line from the building regulator to the fryer <br /> manifold. <br />INLET GAS REQUIREMENTS <br />14” (356mm) IN-N-OUT <br /> 14” (356) <br />Butane 10.1 (257)#33 <br />7/64 <br /> 105,000 (111) <br /> 95,000 (100) <br /> 33 (.90) <br /> 30 (.84) <br />Natural 4.2 (107)#10 <br />#13 <br /> 105,000 (111) <br /> 95,000 (100) <br /> 105 (3.0) <br /> 95 (2.7) <br />Propane 10.0 (254)#31 <br />3.0mm <br /> 105,000 (111) <br /> 95,000 (100) <br /> 42 (1.2) <br /> 38 (1.0) <br />VAT SIZE <br /> Model ZRT3-H <br />IN MM <br />GAS TYPE <br />GAS VALVE PRESSURE <br />(WC) <br /> IN MM <br />ORIFICE HOLE <br /> SIZE <br />RATING <br /> BTU/HR MJ/HR <br />INLET GAS FLOW AT <br />STP <br /> FT3/HR M3/HR <br />NUMBER DESCRIPTION RATING <br />BTU/HR (MJ/HR) <br />24322 3⁄4” (19mm) Diameter Flexible Gas Line (w/quick connect <br />couplings) 48” (1219mm) long. Connect-It SSGC75-48-UCQ 225,000 (238) <br />24323 1” (25mm) Diameter Flexible Gas Line (w/quick connect <br />couplings) 48” (1219mm) long. Connect-It SSGC100-48-UCQ 435,000 (459) <br />24456 11⁄4” (32mm) Diameter Flexible Gas Line (w/quick connect <br />couplings) 48” (1219mm) long. Connect-It SSGC125-48-UCQ 875,000 (924) <br />FLEXIBLE GAS LINES STOCKED BY ULTRAFRYER SYSTEMS <br />J. INLET GAS REQUIREMENTS <br /> The Flexible Gas Line used to connect the gas manifold to the building gas supply line must be rated for the BTU/Hr (MJ/Hr) <br /> designated for the Fryer. Flexible gas lines and their ratings stocked by Ultrafryer Systems are listed below: