Laserfiche WebLink
18 36026.1 010313 <br /> MENU SCREEN ACTION DESCRIPTION <br />CAL LEFT PUMP ? <br />PULL DISPENSE <br />CAL LF PUMP VOL <br />(-) 43mL (+) <br />CAL LF WTR FLOW ? <br />PULL DISPENSER <br />CAL LF WTR VOL <br />(-) 36.0OZ (+) <br />CAL LEFT SIDE ? <br /> EXIT YES <br />CAL RIGHT SIDE ? <br /> EXIT YES <br />If NO - go to CAL RIGHT SIDE menu. <br />CAL LEFT SIDE ? <br /> EXIT YES <br />The following functions are for diagnostic and troubleshooting purposes and typically do not have to be <br />adjusted. Contact your local service agent for assistance before making changes to these functions. <br />RINSE TIME ? <br />(-) 12 Hrs (+) <br />RINSE LOCKOUT ? <br />NO EXIT YES <br />BIB EMPTY LOCKOUT <br />NO EXIT YES <br />BREW LOCKOUT ? <br />NO EXIT YES <br />DLY REPEAT DISP <br />(-) 0 SEC (+) <br />Place a 50 mL (#34843.1000) <br />graduated cylinder under the <br />Left dispense tip, then activate <br />the Left Dispenser <br />Use the (+) or (-) buttons to <br />enter volume collected <br />Place a 64 Oz. (2000 mL) <br />container under the Left <br />dispense tip, then activate the <br />Left Dispenser <br />Use the (+) or (-) buttons to <br />enter volume collected <br />NONE <br />Select (YES) to enable <br />Calibration routine. <br />Select (YES) to enable <br />Use the (+) or (-) buttons to <br />adjust Rinse Alarm delay <br />Select (YES) to enable <br />Select (YES) to enable <br />Select (YES) to enable <br />Use the (+) or (-) buttons to <br />adjust the Delay Time <br />The Left Pump will dispense concentrate for 20 <br />seconds, then shut off automatically. Collect and <br />measure the concentrate dispensed. <br />Enter the volume of concentrate measured from <br />the Left Pump in mL, (not Oz.) regardless of <br />Preferred Units selected. <br />The Left Dispenser will dispense hot water for 20 <br />seconds, then shut off automatically. Collect and <br />measure the water dispensed. <br />Enter the volume of the water measured from the <br />Left dispenser in Oz. (mL). <br />Scroll down to bypass this screen. <br />Selecting Yes will enable the Right Dispenser <br />Calibration routine, (see Pump Calibration) prior <br />to calibrating the dispenser. <br />Selecting Yes will enable the Left Dispenser <br />Calibration routine, (see Field Calibration before <br />attempting to calibrate the dispenser). <br />Enter the desired time between required Rinse <br />Cycles in hours, [8 - 24 hrs.] <br />Select YES to Lockout dispensing until the Rinse <br />Alarm has been cleared. Default is NO <br />Select YES to Lockout dispensing until the <br />Concentrate BIB has been replaced. Default is <br />NO <br />Select YES to Lockout dispensing until the hot <br />water tank is at READY Temp. Default is NO <br />Enter the desired time delay before allowing the <br />next dispense to take place, [0 - 10 sec.] <br />RELEASED FOR PRODUCTION <br />DIR Num: 36026.0001 19, May 2015