Laserfiche WebLink
19 36026.1 010313 <br /> MENU SCREEN ACTION DESCRIPTION <br />CAL RIGHT PUMP ? <br />PULL DISPENSER <br />CAL RT PUMP VOL <br />(-) 43mL (+) <br />CAL RT WTR FLOW <br />PULL DISPENSER <br />CAL RT WTR VOL <br />(-) 36.0OZ (+) <br />CAL RIGHT SIDE ? <br /> EXIT YES <br />CAL HOT WTR FLO ? <br />PULL DISPENSE <br />CAL HOT WTR VOL <br />(-) 34.0OZ (+) <br />XXX CAL -> XXX <br />(-) TankTemp (+) <br />Place a 50 mL (#34843.1000) <br />graduated cylinder under <br />the Right dispense tip, then <br />activate the Right Dispenser <br />Use the (+) or (-) buttons to <br />enter volume collected <br />Place a 64 Oz. (2000 mL) <br />container under the Right <br />dispense tip, then activate the <br />Right Dispenser <br />Use the (+) or (-) buttons to <br />enter volume collected <br />NONE <br />Place a 64 Oz. (2000 mL) <br />container under the Hot Water <br />dispense tip, then activate the <br />Hot Water Dispenser <br />Use the (+) or (-) buttons to <br />enter volume collected <br />Use the (+) or (-) buttons to <br />adjust temperature reading <br />The Right Pump will dispense concentrate for <br />20 seconds, then shut off automatically. Collect <br />and measure the concentrate dispensed. <br />Enter the volume of concentrate measured from <br />the Right Pump in mL(not Oz.) regardless of <br />Preferred Units selected. <br />The Right Dispenser will dispense hot water for <br />20 seconds, then shut off automatically. Collect <br />and measure the water dispensed. <br />Enter the volume of the water measured from the <br />Right dispenser in Oz. (mL) <br />Scroll down to bypass this screen. <br />The Hot Water Dispenser will dispense for 20 <br />seconds, then shut off automatically. Collect and <br />measure the water dispensed. <br />Enter the volume of the water measured from the <br />Hot Water Dispenser in Oz. (mL) <br />Adjust the display reading to match a calibrated <br />probe inserted next to the Tank Sensor, °F (°C). <br />If NO - skip to next menu. <br />Used to set the maximum adjustment the Flavor <br />Guard feature is allowed to make, [3 - 15%]. <br />Displays the Left Dispenser target RPM and <br />Conductance Reading, (Diagnostics Only) <br />Displays the Right Dispenser target RPM and <br />Conductance Reading, (Diagnostics Only) <br />Use the (+) or (-) buttons to <br />adjust % value <br />NONE <br />NONE <br />FlvrGrdRange 10% <br />(-) EXIT (+) <br />LfFlvrGrdTargets <br />RPM XXX-CON XXX <br />RtFlvrGrdTargets <br />RPM XXX-CON XXX <br />For Portion Control Dispensers (LCR-2 PC, LCR-2C PC, LCR-2A PC) only <br />RELEASED FOR PRODUCTION <br />DIR Num: 36026.0001 19, May 2015