Laserfiche WebLink
35 <br />Field Calibrating the Empty BIB Warning <br />The dispenser will automatically turn on the Left or Right “REFILL LED”, see Operating Controls and Interface, <br />when the corresponding BIB is Empty. The Refill message is triggered when the FlavorGardTM sensor reading <br />drops below the minimum setting. The factory set minimum is 500 and should be correct for most locations. <br />However, in some areas the hardness of the local water supply may effect this reading. If the Refill message <br />doesn’t come on when the BIB is empty or the message comes on too early and there is still concentrate left in <br />the BIB, use the following procedure to find the correct Empty BIB threshold. <br />Calibrating The Empty BIB Threshold <br />1. Remove the lower splash guard assembly to access the digital programming module with LCD display. <br />2. Open the cabinet door and set the Function Switch to the “Rinse” position. Close the door. <br />3. Place a large container under the Left dispenser tip, then activate and hold the left dispenser. <br />4. Dispense long enough to rinse all the concentrate out of the mix chamber and for the Conductance reading <br />to stabilize and stop dropping. <br />5. Record the nominal Conductance value displayed. (NOTE: It is typical for this value fluctuate (+/- 25) points <br />about the nominal value}. This is the conductance reading of the water in your area. <br />6. Repeat steps 3, 4 & 5 for the Right dispenser. <br />7. Add 100 points to the larger of the Left or Right side Conductance value. This is the new Empty BIB threshold <br />value for your dispenser. <br />8. Enter this new value into the Empty BIB Alarm threshold, see Programming the Dispenser. <br />36026.1 010313 <br />RELEASED FOR PRODUCTION <br />DIR Num: 36026.0001 19, May 2015