Laserfiche WebLink
OPERATION <br />Operating Instructions <br />NOTES! <br /> This unit is equipped with a photoelectric sensor. <br />Motor is equipped with a thermal sensor that protects the motor from burning up. If motor has <br />been operated under maximum load by 20 complete cycles (continuously running up and <br />down) the motor will shut down for protection. Let motor cold down for at least 10 minutes <br />before resume operations. <br />1. Power lift unit must be leveled and bolted to the wall before its initial use. <br />2. Roll in cart onto the lifting tongue until the two metal bumpers touch the front face of <br />the lifting tongue. <br />3. Press the button labeled up to move lifting tongue up or press button labeled down to <br />move lifting tongue down. Lifting tongue will keep moving up or down as longer button <br />is press and will stop as soonest button gets release. When the lifting tongue is all the <br />way up or down, the motor clutch will engage and will produce a ratcheting sound, this <br />ratcheting does not affect the motor performance, but if unit is operated under over <br />load conditions (above 600 lbs) the motor will heat up and will stop working. If this <br />occurs remove some load and let motor cool down for 10-15 minutes. <br />4. The Emergency stop switch (RED BUTTON) may be pressed at anytime during a cycle to <br />completely stop the motor. <br />5. This equipment is intended for a short time operation when fully loaded at 450lbs to <br />600 lbs and will operate for 20 continuous cycles. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />Serial tag