Laserfiche WebLink
G G GAS <br /> CW COLD WATER 0 <br /> HW HOT WATER <br /> CD CONDENSATE DRAIN <br /> o W WASTE <br /> F <br /> W z ------ V VENT �— <br /> o0 4 <br /> �OCOw <br /> F <br /> wo 0 0 <br /> oz <br /> �o F � O <br /> a� <br /> o <br /> =of <br /> coLL <br /> = LEGEND N.T.S. D s <br /> LU 5 <br /> 0-0 <br /> 5 <br /> Ms 1.ALL PLUMBING WORK&MATERIALS TO BE INSTALLED IN ACCORDANCE WITH ALL vM) architecture <br /> 01 o APPLICABLE STATE&LOCAL CODES&REGULATIONS. CONTRACTOR TO OBTAIN ALL — — — — <br /> w a APPROVALS REQUIRED FROM REGULATING AGENCIES BEFORE STARTING WORK.ALL �f© Design Planning Interiors <br /> o PLUMBING WORK&MATERIALS TO MEET THE REQUIREMENTS OF THE LATEST EDITION OF THE 637 5th Avenue San Rafael, CA 94901 <br /> CO CALIFORNIA PLUMBING CODE. OBTAIN &PAY FOR ALL PERMITS, FEES&INSPECTIONS s 415-451-2500 415-451-2595 fax <br /> REQUIRED BY GOVERNING AUTHORITIES. www.vmarch.com <br /> LU 0 <br /> o<2 . PRIOR TO COMMENCING WORK ON THIS PROJECT, CONTRACTOR SHALL VERIFY DEPTH, ❑ O O O Ms 1 12 <br /> I VMI JOB NUMBER <br /> o SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES IN FIELD BEFORE STARTING _ 10 1861 <br /> w Lu WORK. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE <br /> 0" THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY. <br /> _— / Q <br /> Z o 3. CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER ` 13 <br /> o w TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR TO 16 9 ����'� ARCFIJ� <br /> z REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS. 2s 14 J ti� WAR <br /> o 15 �� I <br /> o m 4.WATER PIPING TO BE TYPE L COPPER MATCHING EXISTING,TYPE K BELOW FLOOR. 21 17 1s 30 <br /> IL m 2g — C �b <br /> o w 5.WASTE AND VENT PIPING TO BE CAST IRON OR ABS DWV WHERE ALLOWED. (E)11/2" <br /> J * No. C17928 <br /> o a 7. NEW GAS PIPING TO BE SCHEDULE 40 BLACK STEEL, GALVANIZED ON ROOF. 22 L 1 2s we 1 I I ( REN. 10/31/19 <br /> 2s <br /> cn <br /> O 1 il/2" <br /> LU W <br /> EL 8. NEW WASTE PIPING TO BE RUN AT 2%MINIMUM SLOPE. 1/2" TP 1 20 � � r0���� <br /> o ❑ 25 FD 1 C7 0� C 1L�i <br /> R Q 10. NEW HOT WATER PIPING TO BE WRAPPED WITH 1"THICK JACKETED FIBERGLASS 11/4" <br /> LOU W ISULATION. PROVIDE INSULATION SHIELDS AT PIPE HANGERS AND SUPPORTS. INSULATION 1" 1/2" <br /> 0 <br /> 0 a- <br /> 00 FOR HOT WATER PIPING TO COMPLY WITH THE REQUIREMENTS OF SECTION 120.3 OF THE 2016 C <br /> o cn= CALIFORNIA ENERGY CODE. z4 we i <br /> 00 L - - <br /> o 11. INSTALL SHUTOFF VALVES ON ALL HOT&COLD WATER LINES TO FIXTURE OR APPLIANCE. 1/2" <br /> o ALL EXPOSED WATER AND WASTE LINES SHALL BE CHROME PLATED. 19 <br /> LF <br /> ww <br /> Uj <br /> } 12. REMOVE ALL ABANDONED PIPING TO REMOVED FIXTURES&EQUIPMENT, CAPPING BEHIND 25 FD 1 17 WH 1&2 27 <br /> cn Z FINISHED SURFACES. 22 L 1 r J <br /> go 06 66 <br /> w <br /> U)COO <br /> 13. RELOCATE PLUMBING PIPING (WATER, WASTE&VENT)TO NEW FIXTURE&EQUIPMENT 21 2s „ <br /> o <br /> Z CONNECTIONS AS REQUIRED. 3/4 <br /> z <br /> w o <br /> 0 0 14. PROVIDE ACCESSABLE WATER HAMMER ARRESTORS OR AIR CHAMBERS WHERE REQUIRED <br /> Q BY THE CALIFORNIA PLUMBING CODE. <br /> az <br /> vS o <br /> z 15.ARRANGE FOR SAWCUTTING AND PATCHING EXISTING CONCRETE FLOOR SLAB AS <br /> o REQUIRED FOR INSTALLATION OF NEW UNDER FLOOR PIPING. <br /> 0 <br /> vi w <br /> o'm 16. SLEEVES TO BE PROVIDED TO PROTECT ALL NEW PIPING PASSING THRU CONCRETE FLOOR <br /> �Z <br /> SLABS PER REQUIREMENTS OF CPC 312.10. <br /> LL O <br /> w�~ 17. NEW OR REPAIRED POTABLE WATER PIPING TO BE DISINFECTED PRIOR TO USE PER <br /> ¢ <br /> Z> REQUIREMENTS OF CPC 609.9. <br /> U Z <br /> 0 18.ALL NEW PIPING IN BUILDING TO BE SUPPORTED&SEISMICALLY BRACED PER RECORD DATES <br /> w REQUIREMENTS OF 2016 CBC&CPC.p j DD SUBMITTAL <br /> �ZPLUMBING FLOOR PLAN 1/4" = 1'-0" A <br /> LU m 19. NEW CLEANOUTS TO BE INSTALLED WHERE REQUIRED BY 2016 CPC&BE READILY BLDG.SUBMITTAL 12/03/2018 <br /> ACCESSIBLE.THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH RECONNECT RELOCATED BEVERAGE UNIT&ICE MACHINE DRAINS TO EXISTING FLOOR SINK ALONG WITH SODA&WATER TUBING. BID SET <br /> EQUIPMENT, CABINETS, ETC. PRIOR TO ANY INSTALLATION. COLD HOT WASTE WATER CONTRACT SET <br /> ITEM FIXTURE WASTE VENT WATER WATER GAS FU FU DESCRIPTION MANUFACTURER/MODEL NUMBER (�f) EXISTING FRUTISTA MACHINE TO BE REMOVED&REINSTALLED FOR COUNTER REFINISHING.ARRANGE FOR RECONNECTION TO <br /> z o EXISTING SODA TUBING. REVISIONS <br /> o 20. NEW LAVATORIES AND WATER CLOSETS TO BE INSTALLED PER CALIFORNIA STATE <br /> HANDICAPPED ACCESSIBILITY REQUIREMENTS. WATER WHITE VITREOUS CHINA FLOOR MOUNTED PRESSURE ASSISTED FLUSH TANK TYPE, (:IDCONNECT NEW WALL MOUNTED HAND SINK TO EXISTING COLD WATER, HOT WATER,WASTE&VENT THAT SERVED REMOVED <br /> o Q WC 1 CLOSET 4" 2" 1/2" -- 4 2.5 ELONGATED BOWL,ADA COMPLIANT, 1.1 GPF WITH BOLT CAPS,TANK COVER LOCKS, AM. STD. CADET/MODEL: 2467.100 COUNTERTOP HAND SINK,VERIFY POINTS OF CONNECTION. <br /> Z O 21. LOCATIONS OF EXISTING WATER&WASTE PIPING SERVING EXISTING TOILET ROOM OLSENITE #95 OPEN FRONT SEAT LESS COVER AND SPEEDWAY SUPPLY. ® EXISTING PREP SINK TO REMAIN. <br /> FIXTURES ARE UNKNOWN &TO BE VERIFIED IN FIELD BEFORE STARTING WORK. <br /> Q~ WHITE VITREOUS CHINA,WALL HUNG,ADA COMPLIANT WITH CONCEALED ARM SUPPORT, AMERICAN STD. COMRADE 0124.131 EXISTING FLOOR SINK TO REMAIN. <br /> 0 <br /> 4"CENTERS, INTEGRAL BACKSPLASH, FLAT GRID STRAINER, METERING TYPE FAUCET, <br /> U) <br /> L 1 LAVATORY 2" 1-1/2" 1/2" 1/2" 1 1 17 GAUGE P-TRAP&SPEEDWAY SUPPLIES. WITH A.S. 1340.225 METERING FAUCET © EXISTING FLOOR DRAIN TO REMAIN. <br /> r <br /> o Z (�Z:) INSTALL NEW NICKEL-BRONZE GRATE WITH FUNNEL ON EXISTING FLOOR DRAIN. <br /> UJ 0 24"x24"x12" PRECAST TERRAZZO WITH 6"HIGH THRESHOLD, STAINLESS STEEL CAP ON ALL FIAT TSB-3000 ® NEW 3 COMPARTMENT POWER SOAK SINK TO REPLACE EXISTING 3 COMPARTMENT SINK, RECONNECT TO EXISTING WATER&WASTE <br /> Z SIDES, REAR&LEFT SIDE TILING FLANGES, 3"GRID DRAIN &WALL MOUNTED FAUCET ROUGH-INS THRU EXISTING WALL. <br /> N > MS 1 MOP SINK 3" 2" 3/4" 3/4" - 3 3 WITH VACUUM BREAKER. AM. STD. 8344.012 FAUCET <br /> ' EXISTING WALL MOUNTED WATER FILTER TO REMAIN. REROUTE EXISTING PLASTIC DRAIN TUBE THRU NEW 1/2"0 PVC SLEEVE THRU <br /> coa w WALL AS LOW AS POSSIBLE TERMINATED WITH ELBOW OVER RIM OF NEW MOP SINK. <br /> N � WATER GAS FIRED TANKLESS WATER HEATER, 199,000 BTUH INPUT, 6 GPM @ 60 DEGREE RISE TAKAGI T-H3-OS <br /> co o¢ WH 1&2 HEATER -- -- 3/4" 3/4" 1" -- -- RECOVERY RATE WITH OUTDOOR RATING&WALL MOUNTING KITS. WEIGHT= 110 POUNDS 10 1/2"FLUE CONDENSATE DRAIN DOWN IN WALL WITH 90°TERMINATION LOW AS POSSIBLE OVER NEW MOP SINK. <br /> o w w 11 CONNECT 3/4"H&CW TO MOP SINK FAUCET&1/2" H&CW TO HAND SINK FAUCET TO EXISTING 3/4"HOT&COLD WATER DOWN IN WALL. CLIENT <br /> GENERAL NOTES E PRB MANAGEMENT LLC. <br /> a PPP INC. MODEL ULP-50OLP 12 CONNECT NEW MOP SINK DRAIN TO 3"VENTED WASTE FROM REMOVED MOP SINK DRAIN ON OPPOSITE SIDE OF EXISTING WALL. <br /> LU�, TRAP PRIMER VALVE INSTALLED ON BOTTOM CONNECTION ON STOP VALVE THRU WALL WITH <br /> co TRAP 1/2"COLD WATER INTO WALL TO FLOOR DRAIN TRAP PRIMER CONNECTION. 4709 Mangels Blvd. <br /> 0 o z - 13 CONNECT NEW HAND SINK TO EXISTING 2"MOP SINK VENT IN WALL&3"WASTE BELOW FLOOR. <br /> TP 1 PRIMER -- -- 1/2" -- -- -- <br /> CL Farfield,CA 94534 <br /> C, M IX TOP OF PARAPET WALL ABOVE ROOF CONNECT NEW 1"HOT&COLD WATER TO NEAREST EXISTING 1"ALONG WITH 11/4"GAS CONNECTED TO NEAREST EXISTING 2"GAS. <br /> o ¢m f 14 DAVE FULWILER <br /> > w z CAST IRON FLOOR DRAIN WITH FLANGE, INTEGRAL CLAMPING COLLAR,TRAP (]5D EXISTING MOP SINK ALONG WITH ITS WALL MOUNTED FAUCET TO BE REMOVED IN DEMOLITION WORK. <br /> s "a _ PRIMER CONNECTION AND ADJUSTABLE ROUND NICKEL BRONZE STRAINER <br /> o FD 1 FLOOR DRAIN 2" 2" -- -- -- 2 - JR SMITH/MODEL: 2005-A 1s EXISTING WATER HEATER&FLUE THRU ROOF TO BE REMOVED ALONG WITH ABANDONED PIPING.ARRANGE FOR PATCHING OF <br /> 0 _> EXISTING ROOF&ROOFING AT REMOVED FLUE PENETRATION. PROJECT <br /> F= -a $ WATER HEATER MOUNTED HIGH <br /> cm o= WH 1&2 AS POSSIBLE ON WALL,2 WATER 17 EXISTING LAVATORY TO BE REMOVED IN DEMOLITION WORK. TACO BELL REMODEL <br /> a LuHEATERS INSTALLED SIDE BY SIDE NOTE: LAVATORIES AND WATER CLOSETS TO BE INSTALLED PER CALIFORNIA STATE HANDICAPPED ACCESSABILITY REQUIREMENTS. <br /> 4 012 1 18 EXISTING WATER CLOSET TO BE REMOVED IN DEMOLITION WORK. 3507 W HAMMER LANE <br /> NI w 7 19 EXISTING URINAL TO BE REMOVED IN DEMOLITION WORK. STOCKTON,CA 95219 <br /> co <br /> � = <br /> 20 1/2"COLD WATER FROM EXISTING NEAR BY TO ACCESSABLE TRAP PRIMER TP-1 ADJACENT TO T-BAR CEILING. RUN INDIVIDUAL 1/2"CW <br /> C:) <br /> f Q 6j 4 FLASH PIPE PENETRATIONS THRU WALL WATER DOWN IN WALL FROM TP-1 TO BELOW FLOOR TO EACH OF 2 FLOOR DRAINS. STORE#2832 <br /> > o TIGHT,PIPE INSULATION JACKET TO EXTEND THRU <br /> o Z 3 FLASHING INTO WALL 21 INSTALL NEW CHROME PLATED WALL ACCESS PLATE TO REPLACE EXISTING COVERING EXISTING CLEANOUT IN WALL. <br /> Z� <br /> wo s s ROOF 22 NEW LAVATORY TO REPLACE EXISTING AT SLIGHTLY OFFSET LOCATION ALONG EXISTING WALL, CONNECT TO EXISTING ROUGH-INS <br /> �I THRU WALL PROVIDING NEW SUPPLIES&P-TRAP. <br /> of Z w z 23 NEW WATER CLOSET TO REPLACE EXISTING AT SLIGHTLY OFFSET LOCATION ON EXISTING WALL, CONNECT TO WATER ROUGH-IN THRU 4QCOO <br /> o w WALL PROVIDING NEW SUPPLY&4"VENTED WASTE FROM ADJACENT REMOVED WATER CLOSET.CO <br /> o�n n <br /> NI =w 1O WRAP EXTERIOR WATER PIPING WITH ALUMINUM JACKETED INSULATION 24 1/2"COLD WATER,4"WASTE&2"VENT TO NEW WATER CLOSET FROM EXISTING PIPING (LOCATIONS UNKNOWN), POINTS OF 7L�L� <br /> E m El <br /> O2 EXPANSION TANK PER CPC REQUIREMENTS ABOVE CEILING CONNECTION TO BE FIELD VERIFIED. M 1 O H <br /> _ o 3/a"COLD WATER TO WATER HEATER FROM COMMON 1"IN WALL 25 CONNECT NEW FLOOR DRAIN TO EXISTING 2"VENTED WASTE THAT SERVED FLOOR DRAIN IT IS REPLACING. CONNECT UNDERFLOOR <br /> of o¢ ® 3/4"120 DEGREE HOT WATER FROM WATER HEATER TO COMMON 1"IN WALL 1/2"COLD WATER FROM TRAP PRIMER TO TRAP PRIMER CONNECTION. <br /> Z J ( 1"GAS TO WATER HEATER FROM COMMON 11/4"IN WALL 2s 1"HOT&COLD WATER, 11/4"GAS, 3/4"FLUE CONDENSATE&T&P RELIEF VALVE DRAIN UP TO WATER HEATERS ON ROOF. TERMINATE <br /> U) Z= T&P RELIEF VALVE DRAIN THRU EXTERIOR WALL PER CODE <br /> � �N © COMBINATION TEMPERATURE AND PRESSURE RELIEF VALVE WITH FULL SIZE <br /> ml a COPPER DRAIN FLASHED WATER TIGHT INTO PARAPET WALL&DROPPING TO <br /> [ o Z TERMINATION POINT THRU EXTERIOR WALL PER CODE 27 2 NEW TANKLESS WATER HEATERS MOUNTED ON ROOF WELL WALL, SEE WATER HEATER DETAIL. <br /> _I U)< O7 1/2"PVC CONDENSATE DRAIN INTO WALL TO COMMON 1/2"DRAIN FLASHED EXISTING WALL TO BE REMOVED IN DEMOLITION WORK,TYPICAL. PLUMBING <br /> C.0 z WATER TIGHT INTO PARAPET WALL&DROPPING ABOVE CEILING TO 28 <br /> 2? �w w TERMINATION POINT OVER MOP SINK <br /> z_ ® SEISMICALLY MOUNT WATER HEATER TO STUDS OR BLOCKING PER CPC 29 OUTLINE OF EXISTING ROOF WELL ABOVE. PLAN <br /> E REQUIREMENTS USING MANUFACTURER'S WALL MOUNTING KIT.SEAL <br /> a o ANY WALL PENETRATIONS WATERTIGHT so EXISTING 11/2"COLD WATER SUPPLY WITH SHUT-OFF VALVE IN VALVE BOX. <br /> cc uioz ( COMMON 1"COLD WATER SUPPLY ABOVE CEILING <br /> �i '�'- <br /> m F'-w <br /> w <br /> � o� <br /> z <br /> 0 �� <br /> WATER HEATER DETAIL D PLUMBING FIXTURE & EQUIPMENT SCHEDULE C KEY NOTES B <br />