My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2200 - Hazardous Waste Program
>
PR0220086
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 6:24:14 PM
Creation date
8/17/2020 2:34:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0220086
PE
2250
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
847
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN" J D�l+ �� I 1411" Environmental Health Department <br /> COUNTY�l <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> OWENS-BROCKWAY GLASS CONTAINER INC 1 14700 W SCHULTE RD TRACY June 05 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 503 CCR 66265.192(k) Hazardous waste tank assessment is incomplete. <br /> The hazardous waste tank assessments for the two 1,000-gallon used oil tanks are incomplete. Tightness testing for <br /> each tank and its ancillary equipment is missing. <br /> The hazardous waste tank assessment shall include all of the following information: <br /> 1.tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity(in gallons); <br /> 2. design standard(s), if available, according to which the tank and ancillary equipment were or will be constructed <br /> and all of the following information: <br /> A. material of construction; <br /> B. material thickness and the method used to determine the thickness; <br /> C. description of tank system piping (material, diameter); <br /> D. description of any internal and external pumps; and <br /> E. sketch or drawing of tank including dimensions. <br /> 3. documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br /> age); <br /> 4. description and evaluation of any leak detection equipment; <br /> 5. description and evaluation of any corrosion protection equipment, devices, or material; <br /> 6. description and evaluation of any spill prevention or overfill equipment; <br /> 7. description and evaluation of secondary containment for the tank system including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265.193(f); <br /> 8. hazardous characteristics of the wastes that have been or will be handled. <br /> 9. prior to placing a new tank system or component in use, an independent, qualified installation inspector or an <br /> independent, qualified, professional engineer, registered in California, either of whom is trained and experienced in the <br /> proper installation of tank systems, shall inspect the system or component for the presence of any of the following <br /> items and document in writing the results of the inspection: <br /> A.weld cracks or breaks; <br /> B. scrapes of protective coatings; <br /> C. corrosion; <br /> D. any structural damage or inadequate construction or installation such as cracks, punctures, damaged <br /> fittings.All discrepancies shall be documented in the assessment and remedied before the tank system is placed in <br /> use. <br /> 10. all new tanks and ancillary equipment shall be tested for tightness prior to being placed in use.The results of <br /> the test(s)shall be documented in this assessment.Tank system integrity or leak test requirements must be in <br /> compliance with all local requirements. Prior to conducting a tank system integrity test or leak test, contact local <br /> agency staff for local requirements. <br /> 11. estimated remaining service life of the tank system based on findings of sections(1)through (10). <br /> Immediately amend the tank system assessment to include all required information and submit a copy of the <br /> amendments to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0006674 PR0220086 SCO01 06/05/2019 <br /> EHD 22-03 Rev.09/27/2018 Page 11 of 13 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.