ACCESSIBILITY REQUIREMENTS
<br /> COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE LOCATED IN THE PICTOGRAM FIELD. §11 B-703.6.1
<br /> 19. WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS SHALL MEET THE REQUIREMENTS OF SECTIONS 11B-604.8.1 ELEVATORS POSTED IN THE BUILDING LOBBY ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, B. PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH
<br /> WHEELCHAIR ACCESSIBLE COMPARTMENTS AND 1113-604.8.3 COAT HOOKS AND SHELVES. INCLUDING THE ISA COMPLYING WITH 11 B-703.7.2.1 ISA. §11 B-216.7 THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. 6qD 33 1?
<br /> COMPARTMENTSCONTAINING MORE THAN ONE PLUMBING FIXTURE SHALL COMPLY WITH SECTION 11 B-603 §11 B-703.6.2
<br /> TOILET AND BATHING ROOMS. AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY WITH SECTIONS 11. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING C. PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT
<br /> 11 B-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS AND 11 B-604.8.3 COAT HOOKS AND SHELVES. ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11 B-703.7.2.6 TOILET AND BATHING DESCRIPTORS SHALL COMPLY WITH 11 B-703.2 RAISED CHARACTERS, 11 B-703.3 BRAILLE AND 11 B-703.4
<br /> §11B-604.8 ROOM GEOMETRIC SYMBOLS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH INSTALLATION HEIGHT AND LOCATION. §11B-703.6.3 WPO 20. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES WIDE MINIMUM MEASURE PERPENDICULAR TO 11 B-603 TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST 21. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. SYMBOLS OF
<br /> THE SIDE WALL, AND 56 INCHES DEEP MINIMUM FOR WALL HUNG WATER CLOSETS AND 59 INCHES DEEP COMPLIANT TOILET ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE PROVIDED. SIGNS SHALL COMPLY ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER A LIGHT SYMBOL ON A DARK
<br /> MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. WHEELCHAIR WITH 1113-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND. §11B-703.7.1
<br /> ACCESSIBLE COMPARTMENTS FOR CHILDREN'S USE SHALL BE 60 INCHES WIDE MINIMUM MEASURED COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 22. SYMBOLS SHALL COMPLY WITH THE FOLLOWING:
<br /> PERPENDICULAR TO THE SIDE WALL, AND 59 INCHES DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED A. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH FIGURE 11B-703.7.2.1 ISA. THE SYMBOL
<br /> WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. §11B-604.8.1.1 12. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE COLOR NO. 15090 IN
<br /> 21. IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH AN IN-SWING DOOR, A MINIMUM 60 INCHES WIDE BY 36 ROOMS, THE TOILET ROOMS OR BATHING ROOMS COMPLYING WITH 1113-603 TOILET AND BATHING ROOMS SHALL FEDERAL STANDARD 595B. §11B-703.7.2.1 (SEE EXCEPTION) SJB Brands, LLC
<br /> INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE CLEARANCE REQUIRED IN SECTION BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. B. THE INTERNATIONAL SYMBOL OF TTY SHALL COMPLY WITH FIGURE 11B-703.7.2.2. 17915 SKY PARK CIRCLE, SUITE J,
<br /> 11B-604.8.1.1 WHEELCHAIR ACCESSIBLE COMPARTMENT SIZE. §11B-604.8.1.1.1, FIGURES 11B-604.8.1.1.2(B) §11B-216.8 C. TELEPHONES WITH A VOLUME CONTROL SHALL BE IDENTIFIED BY A PICTOGRAM OF A TELEPHONE HANDSET IRVINE, CA 92614
<br /> AND 11B-604.8.1.1.3(B) WITH RADIATING SOUND WAVES ON A SQUARE FIELD SUCH AS SHOWN IN FIGURE 11B-703.7.2.3.
<br /> 13. WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE EXCEPTIONS D. ASSISTIVE LISTENING SYSTEMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING TEL: (949)475-0146
<br /> 22. IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A SIDE-OPENING DOOR, EITHER IN-SWINGING OR TO 11 B-213.2 TOILET AND BATHING ROOMS, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH 11 B-603 LOSS COMPLYING WITH FIGURE 11 B-703.7.2.4. FAX:(949)475-0137
<br /> OUT-SWINGING, A MINIMUM 60 INCHES WIDE AND 60 INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) E. ROOMS, FACILITIES AND PATHS OF TRAVEL THAT ARE ACCESSIBLE TO AND USABLE BY PEOPLE WHO ARE
<br /> FRONT OF THE WATER CLOSET. §11 B-604.8.1.1.2, FIGURE 11 B-604.8.1.1.2 COMPLYING WITH 11 B-703.7.2.1 ISA UNLESS ALL TOILET ROOMS AND BATHING FACILITIES COMPLY WITH ADVERSELY IMPACTED BY AIRBORNE CHEMICALS OR PARTICULATES) AND/OR THE USE OF ELECTRICAL FIXTURES
<br /> 11 B-603 TOILET AND BATHING ROOMS. §11 B-216.8 AND/OR DEVICES SHALL BE IDENTIFIED BY THE CLEANER AIR SYMBOL COMPLYING WITH FIGURE 11 B-703.7.2.5.
<br /> 23. IN A WHEEL CHAIR ACCESSIBLE COMPARTMENT WITH END-OPENING DOOR (FACING WATER CLOSET), EITHER THIS SYMBOL IS TO BE USED STRICTLY FOR PUBLICLY FUNDED FACILITIES OR ANY FACILITIES LEASED OR THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
<br /> IN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES WIDE AND 48 INCHES DEEP MANEUVERING SPACE SHALL 14. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS RENTED BY STATE OF CALIFORNIA, NOT CONCESSIONAIRES. ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN
<br /> BE PROVIDED IN FRONT OF THE WATER CLOSET. §11 B-604.8.1.1.3, FIGURE 11 B-604.8.1.1.3 FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE THE SYMBOL, WHICH SHALL INCLUDE THE TEXT "CLEANER AIR" AS SHOWN, SHALL BE DISPLAYED EITHER AS A THE PROPERTY OF GARY WANG & ASSOCIATES; AND NO PART
<br /> DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING NEGATIVE OR POSITIVE IMAGE WITHIN A SQUARE THAT IS A MINIMUM OF 6 INCHES ON EACH SIDE. THE THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN
<br /> 24. TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11 B-404 DOORS, WITH 11 B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) SYMBOL MAY BE SHOWN IN BLACK AND WHITE OR IN COLOR. WHEN COLOR IS USED, IT SHALL BE CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
<br /> DOORWAYS, AND GATES EXCEPT THAT IF THE APPROACH IS FROM THE PUSH SIDE OF THE COMPARTMENT DOOR, COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 FEDERAL BLUE COLOR NO. 15090 FEDERAL STANDARD 5956 ON WHITE, OR WHITE ON FEDERAL BLUE. SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND
<br /> ( ) DEVELOPED WITHOUT THE WRITTEN CONSENT OF GARY WANG &
<br /> CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 48 INCHES THERE SHALL BE AT LEAST A 70-PERCENT COLOR CONTRAST BETWEEN THE BACKGROUND OF THE SIGN ASSOCIATES. VISUAL CONTACT WITH THESE DRAWINGS AND
<br /> MINIMUM MEASURED PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION. DOOR SHALL BE 15. SIGNS SHALL COMPLY WITH 1113-703 SIGNS. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, FROM THE SURFACE THAT IT IS MOUNTED ON. §11B-703.7.2.5 SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
<br /> LOCATED IN FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS
<br /> §11 B-604.8.1.2 AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. §11 B-703.1 F. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS;
<br /> A. SIGNS AS SPECIFIED IN SECTION 11 B-703 SIGNS, OR IN OTHER SECTIONS OF THIS CODE, WHEN INCLUDED COMPLYING WITH 11 B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. THE SYMBOL SHALL BE CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL
<br /> 25. WHERE TOILET COMPARTMENT DOORS ARE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE IN THE CONSTRUCTION OF NEW BUILDINGS OR FACILITIES, OR WHEN INCLUDED, ALTERED OR REPLACED DUE TO MOUNTED AT 58 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE
<br /> MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS
<br /> 4 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED ADDITIONS, ALTERATIONS OR RENOVATIONS TO EXISTING BUILDINGS OR FACILITIES, AND WHEN A PERMIT IS MEASURED FROM THE CENTERLINE OF THE SYMBOL. WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAIL MUST
<br /> IN THE SIDE WALL OR PARTITION, THE DOOR OPENING SHALL BE 4 INCHES MAXIMUM FROM THE FRONT REQUIRED, SHALL COMPLY WITH 1113-703.1.1.1 PLAN REVIEW AND 11B-703.1.1.2 INSPECTION. §11B-703.1.1 MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE DOOR. §11B-703.7.2.6 (SEE EXCEPTION) BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING
<br /> PARTITION AND THE DOOR SHALL BE SELF-CLOSING. §11B-604.8.1.2 B. PLANS, SPECIFICATIONS OR OTHER INFORMATION INDICATING COMPLIANCE WITH THESE REGULATIONS SHALL BE WITH THE FABRICATION.
<br /> SUBMITTED TO THE ENFORCING AGENCY FOR REVIEW AND APPROVAL. §11B-703.1.1.1 G. MEN'S TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, �/a INCH THICK
<br /> 26. A DOOR PULL COMPLYING WITH SECTION 11B-404.2.7 DOOR AND GATE HARDWARE SHALL BE PLACED ON C. SIGNS AND IDENTIFICATION DEVICES SHALL BE FIELD INSPECTED AFTER INSTALLATION AND APPROVED BY THE WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL CONTRAST WITH
<br /> BOTH SIDES OF THE DOOR NEAR THE LATCH. DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER CHAPTER 1, DIVISION THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.1 ARCHITECT
<br /> CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS MAY SWING INTO THAT PORTION OF THE MANEUVERING SPACE II, SECTION 111, OR FINAL APPROVAL WHERE NO CERTIFICATE OF OCCUPANCY IS ISSUED. THE INSPECTION
<br /> WHICH DOES NOT OVERLAP THE CLEARANCE REQUIRED AT A WATER CLOSET. §11 B-604.8.1.2 (SEE EXCEPTION) SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFICATION THAT BRAILLE DOTS AND CELLS ARE PROPERLY SPACED H. WOMEN'S TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, �/4 INCH THICK AND 12 INCHES
<br /> AND THE SIZE, PROPORTION AND TYPE OF RAISED CHARACTERS ARE IN COMPLIANCE WITH THESE REGULATIONS. IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND
<br /> 27. AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF 9 INCHES MINIMUM ABOVE THE FINISH §11 B-703.1.1.2 OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.2 Mao
<br /> FLOOR AND 6 INCHES DEEP MINIMUM BEYOND THE COMPARTMENT-SIDE FACE OF THE PARTITION, EXCLUSIVE OF GARY WANG
<br /> PARTITION SUPPORT MEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE SMOOTH WITHOUT SHARP 16. RAISED CHARACTERS SHALL COMPLY WITH 11 B-703.2 RAISED CHARACTERS AND SHALL BE DUPLICATED IN I. UNISEX TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, Y4 INCH THICK AND 12 INCHES IN
<br /> EDGES OR ABRASIVE SURFACES. COMPARTMENTS FOR CHILDREN'S USE SHALL PROVIDE A TOE CLEARANCE OF 12 BRAILLE COMPLYING WITH 11B-703.3 BRAILLE. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH DIAMETER WITH A �/a INCH THICK TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE &ASSOCIATES, INC.
<br /> INCHES MINIMUM ABOVE THE FINISH FLOOR. §11B-604.8.1.4 11 B-703.4 INSTALLATION HEIGHT AND LOCATION. §11 B-703.2 AND WITHIN THE 12-INCH DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER
<br /> A. RAISED CHARACTERS SHALL BE 1/32 INCH MINIMUM ABOVE THEIR BACKGROUND. §11B-703.2.1 LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST
<br /> 28. GRAB BARS SHALL COMPLY WITH SECTION 116-609 GRAB BARS. A SIDE-WALL GRAB BAR COMPLYING WITH WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.3 1000 Corporate Center Dr., Suite 550
<br /> SECTION 11 B-604.5.1 SIDE WALL SHALL BE PROVIDED AND SHALL BE LOCATED ON THE WALL CLOSEST TO THE B. CHARACTERS SHALL BE UPPERCASE. §11 B-703.2.2 Monterey Park, CA 91754
<br /> WATER CLOSET. IN ADDITION, A REAR-WALL GRAB BAR COMPLYING WITH SECTION W LLS A 5A REAR WALL J. EDGES OF SIGNS SHALL BE ROUNDED, CHAMFERED OR EASED. CORNERS OF SIGNS SHALL HAVE A MINIMUM TEL: (626)288-6898 FAX: (626)768-7101
<br /> SHALL BE PROVIDED. WHERE SEPARATE GRAB BARS ARE REQUIRED NA ADJACENT WALLS ATA COMMON C. CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY RADIUS OF % INCH. §11B-703.7.2.6.4 http://www.garywang.com
<br /> MOUNTING HEIGHT, AN L-SHAPED GRAB BAR MEETING THE DIMENSIONAL REQUIREMENTS OF SECTIONS DECORATIVEOR OF OTHER UNUSUAL FORMS §11 B-703.2.3
<br /> 11B-604.5.1 SIDE WALL AND 1113-604.5.2 REAR WALL SHALL BE PERMITTED. §11B-604.8.1.5 , . K. POLE-SUPPORTED PEDESTRIAN TRAFFIC-CONTROL BUTTONS SHALL BE IDENTIFIED WITH COLOR CODING
<br /> 29. URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAXIMUM ABOVE D. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "0" IS 55 60 CONSISTING OF A TEXTURED HORIZONTAL YELLOW BAND 2 INCHES IN WIDTH ENCIRCLING THE POLE, AND A
<br /> THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13% INCHES DEEP MINIMUM MEASURED FROM THE OUTER PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". §11B-703.2.4 1-INCH-WIDE DARK BORDER BAND ABOVE AND BELOW THIS YELLOW BAND. COLOR CODING SHALL BE PLACED
<br /> FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE. §116-605.2 IMMEDIATELY ABOVE THE CONTROL BUTTON. CONTROL BUTTONS SHALL BE LOCATED NO HIGHER THAN 48 INCHES STAMP
<br /> E. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH ABOVE THE GROUND SURFACE ADJACENT TO THE POLE. §11B-703.7.2
<br /> 30. A CLEAR FLOOR SPACE OR GROUND SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR OR GROUND MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". §11B-703.2.5
<br /> SPACE POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. §1113-605.3
<br /> F. STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 15 PERCENT MAXIMUM OF THE HEIGHT OF THE H. BUILT-IN ELEMENTS
<br /> 31. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL CHARACTER. §11B-703.2.6 DINING SURFACES AND WORK SURFACES
<br /> COMPLY WITH SECTION 11B-309 OPERABLE PARTS EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT G. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT RAISED �SE� AIR?
<br /> A MAXIMUM HEIGHT OF 44 INCHES ABOVE THE FINISH FLOOR. §11 B-605.4 CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS 1. WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT
<br /> 32. LAVATORIES AND SINKS SHALL COMPLY WITH SECTION 1113-606 LAVATORIES AND SINKS. §11B-606.1 SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8 INCH MINIMUM AND 4 TIMES THE OF THE SEATING SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY WITH 1113-902. IN
<br /> RAISED CHARACTER STROKE WIDTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING ADDITION, WHERE WORK SURFACES ARE PROVIDED FOR USE BY OTHER THAN EMPLOYEES, AT LEAST 5 PERCENT
<br /> 33. FOR LAVATORIES AND SINKS, A CLEAR FLOOR SPACE COMPLYING WITH SECTION 1113-305 CLEAR FLOOR OR BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/16 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER SHALL COMPLY WITH 11B-902. §11B-226.1 (SEE EXCEPTIONS) * N 032569
<br /> GROUND SURFACES, POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING STROKE WIDTH MAXIMUM AT THE BASE OF THE CROSS SECTIONS, AND 1/8 INCH MINIMUM AND 4 TIMES THE 2. DINING SURFACES AND WORK SURFACES REQUIRED TO COMPLY WITH 116-902 SHALL BE DISPERSED RE ,04- - 619
<br /> WITH SECTION 1113-306 KNEE AND TOE CLEARANCE SHALL BE PROVIDED. §11B-606.2 RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING SURFACES AND WORK SURFACES FOR EACH TYPE OF
<br /> SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8 INCH MINIMUM. §11B-703.2.7 SEATING IN A 9 C�
<br /> GRAB BARS H. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE THROUGHOUT THE CSPACE LOR ACILIIYKCONTA CONTAINING WORK SURFACES IRSURFA EOM§11 B-226�1 B-902 SHALL BE DISPERSED OF CAL'
<br /> 1. GRAB BARS WITH CIRCULAR CROSS SECTION IN TOILET FACILITIES AND BATHING FACILITIES SHALL HAVE AN 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER HEIGHT. §11B-703.2.8 3. WHERE FOOD OR DRINK IS SERVED FOR CONSUMPTION AT A COUNTER EXCEEDING 34 INCHES IN HEIGHT, A
<br /> OUTSIDE DIAMETER OF 11/4 INCHES MINIMUM AND 2 INCHES MAXIMUM. §11B-609.2.1 I. TEXT SHALL BE IN A HORIZONTAL FORMAT. §11B-703.2.9 PORTION OF THE MAIN COUNTER 60 INCHES MINIMUM IN LENGTH SHALL BE PROVIDED IN COMPLIANCE WITH
<br /> 1113-902.3. §11B-226.3
<br /> 2. GRAB BARS WITH NON-CIRCULAR CROSS SECTIONS SHALL HAVE A CROSS-SECTION DIMENSION OF 2 INCHES
<br /> MAXIMUM AND A PERIMETER DIMENSION OF 4 INCHES MINIMUM AND 4.8 INCHES MAXIMUM. §11B-609.2.2 17. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH 1113-703.3 BRAILLE AND 11B-703.4
<br /> INSTALLATION HEIGHT AND LOCATION. §11B-703.3 4. QUEUES AND WAITING LINES SERVICING COUNTERS OR CHECK-OUT AISLES REQUIRED TO COMPLY WITH
<br /> 3. SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1% INCHES. THE SPACE BETWEEN THE GRAB BAR 1113-904.3 OR 1113-904.4 SHALL COMPLY WITH 1113-403. §11B-227.5 PROJECT NAME/ADDRESS:
<br /> AND PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 1% INCHES MINIMUM. THE SPACE BETWEEN THE A. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11 B-703.3.1.
<br /> GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES MINIMUM. §11 B-609.3 THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND 5. COUNTERS IN FOOD SERVICE LINES SHALL COMPLY WITH 11 B-904.5. §11 B-904.5
<br /> 4. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM NAMES, INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS. §11 B-703.3.1 A. SELF-SERVICE SHELVES AND DISPENSING DEVICES FOR TABLEWARE, DISHWARE, CONDIMENTS, FOOD AND JUICE IT U P!
<br /> ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS BEVERAGES SHALL COMPLY WITH 11 B-308. §11 B-904.5.1 RIPON TOWN SQUARE
<br /> FOR CHILDREN'S USE COMPLYING WITH SECTION 11 B-604.9 WATER CLOSETS AND TOILET COMPARTMENTS FOR
<br /> CHILDREN'S USE, GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION 18 INCHES MINIMUM AND 27 B. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR B. THE TOPS OF TRAY SLIDES SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH
<br /> INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. §11B-609.4 CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE SHALL BE FLOOR OR GROUND. §11B-904.5.2 1201 W. MAIN ST.,
<br /> SEPARATED 3/8 INCH MINIMUM AND 1/2 INCH MAXIMUM FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH BENCHES
<br /> SIGNS
<br /> MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. §11B-703.3.2 (SEE EXCEPTION) RIPON, CA 95366
<br /> 1. EXCEPT BUILDING DIRECTORIES, MENUS, SEAT AND ROW DESIGNATIONS IN ASSEMBLY AREAS, OCCUPANT 18. SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH 11 B-703.4 INSTALLATION HEIGHT AND LOCATION. CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS
<br /> NAMES, BUILDING ADDRESSES, AND COMPANY NAMES AND LOGOS, NEW OR ALTERED SIGNS SHALL BE PROVIDED §11B-703.4
<br /> IN ACCORDANCE WITH 11 B-216 SIGNS AND SHALL COMPLY WITH 11 B-703 SIGNS. THE ADDITION OF OR 1. SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH EITHER OF THE FOLLOWING AND THE
<br /> REPLACEMENT OF SIGNS SHALL NOT TRIGGER ANY ADDITIONAL PATH OF TRAVEL REQUIREMENTS. §11 B-216.1 A. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR SERVICE
<br /> GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER BRAILLE CELLS AND 60 COUNTER TOP. §11B-904.4 (SEE EXCEPTION) REVISIONS:
<br /> 2. IN PARKING FACILITIES, SIGNS PROVIDED SOLELY FOR THE OPERATION OF VEHICLES SHALL NOT BE REQUIRED INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE 0 _
<br /> TO COMPLY WITH 1113-216.2 DESIGNATIONS, 1113-216.3 DIRECTIONAL AND INFORMATIONAL SIGNS, AND HIGHEST TACTILE CHARACTER LINE OF RAISED CHARACTERS. §11B-703.4.1 (SEE EXCEPTION) A. A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES LONG MINIMUM AND 34 INCHES HIGH MAXIMUM _
<br /> 11B-216.6 THROUGH 11B-216.12. ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 1113-305
<br /> B. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT LL BE POSITIONED FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH MINIMUM LENGTH OF COUNTER. Q3 -
<br /> 3. TEMPORARY, 7 DAYS OR LESS, SIGNS SHALL NOT BE REQUIRED TO COMPLY WITH 11 B-216 SIGNS. THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN §11 SHALL
<br /> BE 41 (SEE EXCEPTION) OR
<br /> SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO . ® -
<br /> 4. INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL COMPLY WITH 11 B-703.1 ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO B. A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES LONG MINIMUM AND 34 INCHES HIGH MAXIMUM 05 -
<br /> GENERAL, 11 B-703.2 RAISED CHARACTERS, 11 B-703.3 BRAILLE AND 11 B-703.5 VISUAL CHARACTERS. WHERE WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL SHALL BE PROVIDED. KNEE AND TOE SPACE COMPLYING WITH 11 B-306 SHALL BE PROVIDED UNDER THE _
<br /> PICTOGRAMS ARE PROVIDED AS DESIGNATIONS OF PERMANENT INTERIOR ROOMS AND SPACES, THE PICTOGRAMS BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO COUNTER. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE POSITIONED FOR A
<br /> SHALL COMPLY WITH 11 B-703.6 PICTOGRAMS AND SHALL HAVE TEXT DESCRIPTORS COMPLYING WITH 11 B-703.2 THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE FORWARD APPROACH TO THE COUNTER. §11B-904.4.2 Q AND 11 B-703.5. §11 B-216.2 (SEE EXCEPTION) CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45
<br /> DEGREE OPEN POSITION. WHERE PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES
<br /> 5. SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND EXTERIOR SPACES AND FACILITIES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS
<br /> OF THE SITE SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. §11B-216.3 THAT IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR ISSUE DATE:
<br /> SPACE. 118-703.4.2 (SEE EXCEPTION)
<br /> 6. SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH 11 B-216.4 MEANS OF EGRESS: 1ST -
<br /> A. SIGNS REQUIRED BY CHAPTER 10, SECTION 1011.4 AT DOORS TO DOORS AT EXIT PASSAGEWAYS, EXIT 19. VISUAL CHARACTERS SHALL COMPLY WITH THE FOLLOWING, EXCEPT WHERE VISUAL CHARACTERS COMPLY
<br /> DISCHARGE, AND EXIT STAIRWAYS SHALL BE IDENTIFIED BY TACTILE SIGNS COMPLYING COMPLY WITH 1113-703.1 WITH 11 B-703.2 RAISED CHARACTERS AND ARE ACCOMPANIED BY BRAILLE COMPLYING WITH 11 B-703.3 BRAILLE, 2ND
<br /> GENERAL, 11 B-703.2 RAISED CHARACTERS, 11 B-703.3 BRAILLE AND 11 B-703.5 VISUAL CHARACTERS. THEY SHALL NOT BE REQUIRED TO COMPLY WITH 11 B-703.5.2 THROUGH 11 B-703.5.6, 11 B-703.5.8 AND 3RD -
<br /> §11 B-216.4.1 11 B-703.5.9:
<br /> 4TH -
<br /> B. SIGNS REQUIRED BY SECTION 1003.2.13.5.4 OF THE INTERNATIONAL BUILDING CODE (2000 EDITION) OR A. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH
<br /> SECTION 1007.6.4 OF THE INTERNATIONAL BUILDING CODE (2003 EDITION) (INCORPORATED BY REFERENCE, SEE 5TH
<br /> THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A
<br /> "REFERENCED STANDARDS" IN CHAPTER 1) CHAPTER 10, SECTION 1007.11 TO PROVIDE INSTRUCTIONS IN AREAS LIGHT BACKGROUND. §11B-703.5.1 6TH
<br /> OF REFUGE SHALL COMPLY WITH 1113-703.5 VISUAL CHARACTERS. SIGNS REQUIRED BY CHAPTER 10, SECTION
<br /> 1007.9 AT DOORS TO AREAS OF REFUGE AND EXTERIOR AREAS FOR ASSISTED RESCUE SHALL COMPLY WITH B. CHARACTERS SHALL BE UPPERCASE OR LOWERCASE OR A COMBINATION OF BOTH. §11B-703.5.2
<br /> 11B-703.1 GENERAL, 1113-703.2 RAISED CHARACTERS, 1113-703.3 BRAILLE AND 11B-703.5 VISUAL
<br /> CHARACTERS AND INCLUDE AN INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 C. CHARACTERS SHALL BE CONVENTIONAL IN FORM. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, JOB NUMBER
<br /> ISA. §11B-216.4.2 HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. §11B-703.5.3
<br /> C. SIGNS REQUIRED BY SECTION 1003.2.13.6 OF THE INTERNATIONAL BUILDING CODE (2000 EDITION) OR
<br /> SECTION 1007.7 OF THE INTERNATIONAL BUILDING CODE (2003 EDITION) (INCORPORATED BY REFERENCE, SEE D. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 55 60 ARCH PROJECT#: 18-287
<br /> "REFERENCED STANDARDS" IN CHAPTER 1) CHAPTER 10, SECTION 1007.10 TO PROVIDE DIRECTIONS TO PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". §11B-703.5.4
<br /> ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH 1113-703.5 VISUAL CHARACTERS. §11B-216.4.3
<br /> D. SIGNS REQUIRED BY CHAPTER 10, SECTION 1008.1.9.7, ITEM 5.1 AT DOORS WITH DELAYED EGRESS LOCKS E. MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE 11B-703.5.5. VIEWING DISTANCE SHALL BE
<br /> SHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 1113-703.3 BRAILLE AND MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHER
<br /> 11B-703.5 VISUAL CHARACTERS. §11B-216.4.4 APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED ON THE UPPERCASE LETTER "I". DRAWN BY CHECKED BY
<br /> 7. PARKING SPACES COMPLYING WITH 11B-502 PARKING SPACES SHALL BE IDENTIFIED BY SIGNS COMPLYING §11B-703.5.5 (SEE EXCEPTION) JR ADR
<br /> WITH 11B-502.6 IDENTIFICATION. §11B-216.5 F. VISUAL CHARACTERS SHALL BE 40 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-703.5.6
<br /> 8. IN RESIDENTIAL FACILITIES, WHERE PARKING SPACES ARE ASSIGNED TO SPECIFIC RESIDENTIAL DWELLING UNITS, (SEE EXCEPTIONS) SHEET CONTENT
<br /> IDENTIFICATION OF ACCESSIBLE PARKING SPACES SHALL NOT BE REQUIRED. G. STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10 PERCENT MINIMUM AND 20 PERCENT
<br /> MAXIMUM OF THE HEIGHT OF THE CHARACTER. §11B-703.5.7 ACCESSIBILITY NOTES
<br /> 9. IN EXISTING BUILDINGS AND FACILITIES WHERE NOT ALL ENTRANCES COMPLY WITH 11 B-404 DOORS, & DETAILS
<br /> DOORWAYS, AND GATES, COMPLIANT ENTRANCES SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF H. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT CHARACTERS,
<br /> ACCESSIBILITY (ISA) COMPLYING WITH 11 B-703.7.2.1 ISA. DIRECTIONAL SIGNS COMPLYING WITH 11 B-703.5 EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL CHARACTERS SHALL BE 10 PERCENT MINIMUM AND 35
<br /> VISUAL CHARACTERS THAT INDICATE THE LOCATION OF THE NEAREST ENTRANCE COMPLYING WITH 11B-404 PERCENT MAXIMUM OF CHARACTER HEIGHT. §11B-703.5.8
<br /> SHALL BE PROVIDED AT ENTRANCES THAT DO NOT COMPLY WITH 1113-404 DOORS, DOORWAYS, AND GATES. SHEET NO
<br /> DIRECTIONAL SIGNS COMPLYING WITH 11 B-703.5 VISUAL CHARACTERS, INCLUDING THE ISA COMPLYING WITH I. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A MESSAGE SHALL BE 135
<br /> 11 B-703.7.2.1 ISA, INDICATING THE ACCESSIBLE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE SHALL BE PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE CHARACTER HEIGHT. §1 1 B-703.5.9
<br /> PROVIDED AT JUNCTIONS WHEN THE ACCESSIBLE ROUTE DIVERGES FROM THE REGULAR CIRCULATION PATH.
<br /> §11B-216.6 (SEE EXCEPTIONS) J. TEXT SHALL BE IN A HORIZONTAL FORMAT. §11B-703.5.10
<br /> 10. WHERE EXISTING ELEVATORS DO NOT COMPLY WITH 1113-407 ELEVATORS, COMPLIANT ELEVATORS SHALL BE 20. PICTOGRAMS SHALL COMPLY WITH THE FOLLOWING:
<br /> CLEARLY IDENTIFIED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 A. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE T� 1 04
<br /> ISA. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC ELEVATORS FOR PUBLIC USE THAT
<br />
|